148
C
HAPTER
6: ILMI C
ONFIGURATION
Enable/Disable
Change of
Attachment-Point
Enables or disables the change of attachment-point mechanism for the
specified port in the CoreBuilder 7000 family ATM switch.
ILMI channel polling must be enabled if the change of attachment-point
facility (COAP) is enabled (“Enable/Disable ILMI Channel Polling” on
page 137).
Before enabling COAP, verify that all attached ATM edge devices support
ILMI 4.0. If they do not, they can fail.
Command Actions
Command Result
Example
Enter:
1 1 8 2 1 3.2 1
The following message is displayed:
Change of attachment-point is set to ENABLED
The change of attachment-point status of port 3.2 is enabled.
Enter the menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(8) IME: ILMI setup
(8) COA: COAP setup
(2) SET: Set&save COAP status
Enter a parameter at the prompt
Parameter
Format or Range
Port ID
slot.port
Change of
attachment-point
enable/disable
0
to disable change of attachment-point
1
to enable change of attachment-point
Direct access sequence:
1 1 8 8 2
[parameters]
System action taken:
The change of attachment-point status is enabled or
disabled for the selected port immediately and is saved
in flash.
System message display:
Change of attachment-point is set to
ENABLED/DISABLED
Содержание CoreBuilder 7000
Страница 16: ......
Страница 68: ...68 CHAPTER 3 GENERAL TASKS ...
Страница 164: ...164 CHAPTER 6 ILMI CONFIGURATION ...
Страница 462: ...462 CHAPTER 13 CONFIGURING AND MANAGING PNNI FOR THE EXTENDED VERSION ONLY ...
Страница 468: ...468 APPENDIX A TECHNICAL SUPPORT ...
Страница 472: ...472 APPENDIX B COREBUILDER 7000 FAMILY ATM SWITCH SPECIFICATIONS ...
Страница 476: ...476 APPENDIX C SAFETY INFORMATION ...
Страница 514: ...514 INDEX ...