9
Recall Last Value
In incremental mode the digital readout can recall the last preset value entered for each axis. This function is useful when
the same move must be repeated several times.
Example: a part requires a series of holes to be drilled at 2.25 inch intervals along the X axis. The recall function can be used
to quickly get the same offset each time
Standard Functions
Step
Buttons
Information Screen
1 Move to the position of the first hole and drill to the desired depth
2 Press X, enter 2.25 on the numpad, and press OK
3 Move the X axis until the X display reads zero and drill the second
hole
4 Press Recall, then press X
5 Move the X axis until the X display reads zero and drill the third
hole
6 Repeat steps 4 and 5 until all of the holes are drilled
Inc Set:
X: 2.25 in
Inc Recall
Press X Y Z Cncl
Sub-datum Mode
Up to 200 sub datum points can be added to define the position of features relative to the absolute origin zero point. When
a sub-datum is selected the DRO will display the distance to the sub-datum position such that when you are at the correct
position the DRO axis displays will read zero. Because all sub-datum features are relative to the absolute mode origin point,
when the origin is moved, as in re-zeroing on a new part, all the sub-datum points will move with it.
To enter into the sub-datum mode recall an existing datum using the REC button. To create a new datum use the SET
button.
When in sub-datum mode, the current sub-datum is shown on the information screen: “DT001” means Datum 001
DT001
TL01 F0.0ipm