X-Ray Inspection System
User Manual
P a g e
| 65
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
2)
Situation 2: The system displays "Failure to open control panel communication".
This is usually caused by a failure of the data transmission line between the control
panel and the industrial motherboard. Check the data line plug (DB9 plug) of COM1
port on the industrial motherboard and the data line plug (white plug of line 3) of J3
port on the control panel to see whether they are loosened or poorly contacted, if
so, re-plug the data line plugs on the two ends.
Failure 4: Keys on the special-purpose keyboard does not work normally
If the equipment boots normally by the key switch and the start button on the special-
purpose keyboard, but the motor key or image processing key did not work, then the
failure is caused by the data line communication on the COM2 port. Check the data line
plug (DB9 plug) on the COM2 port of the industrial motherboard.
Failure 5: The X-Ray Generator does not radiate normally
If the Conveyor runs normally but the ray did not radiate normally and the screen did not
display images, please check the ON/OFF, XRAY_ON and POWER on the X-Ray Controller
to see whether the indicators work normally (During inspection, press the micro-switch
and press the Start button to recover the emergency stop state). Then press the
emergency stop button and check whether the INTERFACE and POWER plug connection
is loosened. If so, please re-plug the control line and check whether the equipment boots
normally.
Failure 6: Power failure
First disconnect the power supply line, then check the air switch for tripping. If the air
switch is tripped, please set it again. You have to wait for one minute, reconnect the
power supply line, and then reboot the security device as usual.
At this point the windows system starts to repair or it starts normally.
If the system starts to repair, connect an external PC keyboard and click Normal Start.