X-Ray Inspection System
User Manual
P a g e
| 53
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
Notes:
If the customer initiates the TIP function, then all the operation results in training
demonstration will be recorded in the system. The system will get the statistical data on
a TIP quantity and the TIP data of all users. The administrator can check the relevant data
in TIP exam query.
4.11.3
Training Procedure
Step 1:
Select the folder to choose the scanned parcel files required in training.
Step 2:
Set the parameters (the save button is used to save the settings and backups).
Step 3:
Click “
Start
” to start the training. The training box can be deleted but it will still
be shown in the menu bar (the icon means the training is going on).
Step 4:
Click any operational key of the conveyor (in training mode, clicking any
operational key of the conveyor will not make the conveyor to move.) or image front-
pulling key, the interface center will show the training images when simulating the
operation of machine based on the parameter setting.
Step 5:
When finding suspicious articles, press "Stop" button of the conveyor and the
"Mark" button on the special-purpose keyboard to mark the image.
Step 6:
If you want to finish the training, click the “
Pause
” button of the conveyor to stop
the moving image and then click the menu or right-click the mouse to select "finish" to
finish the training.
System Settings
This function is accessible by the administrator, including: intelligent identification,
keyboard settings, counter settings and so on.
4.12.1
Intelligent Identification
You can set the "High density alert" and "Drugs and explosives inspection" in the
"intelligent identification" interface; the initiate mode and sensitivity can be set
separately (when checking " " to switch to initiate mode respectively, the alert box of
"High density alert" is red, the alert box of "Drugs and explosives inspection" is pink and