Hydro Tap Installation and Operating Instructions - 86682 - March 2012 v1.05
Read These Warnings First
Safety
This appliance is not intended for use by persons (including children) with
reduced physical sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.. Children should
be supervised to ensure that they do not play with the appliance.
Refrigerant
The Zip HydroTap Chilling unit contains 134A refrigerant under pressure.
No part of the unit should be exposed to a naked flame. Maintenance of the
refrigeration unit must be carried out by an accredited service provider or
qualified refrigeration mechanic.
Qualifications
If the power cable is damaged it must be repaired only by a qualified
technician. To avoid hazards, all installation procedures must be carried out by
a suitably qualified tradesperson. The power cable and power outlet must be in
a safe visible position for connection.
Venting
Sometimes steam and / or boiling water may discharge through a vent outlet at
the mouth of the tap. If the tap is not installed using the Font pedestal, ensure
the tap body is located so the tap outlet safely drains into the sink bowl area.
NOTE:
On startup, the controls take the system through a calibration process
which causes the unit to over-boil for a period of 90 seconds. Once this mode
is completed the system reverts back to normal operation.
Lifting
Take care when lifting the Zip HydroTap undersink unit. Some units may
exceed safe lifting guidelines. If you feel this is beyond your personal
capabilities, please seek assistance with the lift. The weights of the units are
marked on the packaging and are given in the table on P6. Do not lift the unit
by the doors.
Airflow
The ambient temperatures this unit should operate within are 5ºC - 35ºC.
Proper air circulation must be provided. The system will operate satisfactorily
only if the recommended air gaps are provided, these are 65mm min rear
clearance and 50mm side clearance. An air vent is provided with each unit for
high usage applications, this must be installed in the top half of the cupboard
door as a matter of course. An accessory exhaust fan kit is available and when
supplied should always be fitted to ensure adequate ventilation. Make sure
that the ventilation grilles of the undersink unit are not obstructed.
I
ncluded in
the installation pack are adhesive backed silicon buffers. If air vents are not
installed in the cupboards housing the HydroTap, the buffers must be placed
on the inside edge of the cupboard door to create a slight gap ensuring a
minimum airflow. Failure to do this may cause the HydroTap to overheat and
operate inefficiently.
Altitude
The Zip HydroTap is equipped with a self-calibrating program which caters for
altitude adjustment.
Zip Hydrotap undersink assembly.
The appliance must be placed in a
horizontal position, as shown above.
The power point must be located within
reach of its cable. The power lead is
supplied with the plug head removed to
facilitate ease of fitting to a 13 amp fused
spur. The appliance must be positioned so
that the power point is accessible.