Hydro Tap Installation and Operating Instructions - 86682 - March 2012 v1.05

 Read These Warnings First

Safety

This appliance is not intended for use by persons (including children) with 
reduced physical sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.. Children should 
be supervised to ensure that they do not play with the appliance.

Refrigerant

The Zip HydroTap Chilling unit contains 134A refrigerant under pressure. 
No part of the unit should be exposed to a naked flame. Maintenance of the 
refrigeration unit must be carried out by an accredited service provider or 
qualified refrigeration mechanic.

Qualifications

If the power cable is damaged it must be repaired only by a qualified 
technician. To avoid hazards, all installation procedures must be carried out by 
a suitably qualified tradesperson. The power cable and power outlet must be in 
a safe visible position for connection.

Venting

Sometimes steam and / or boiling water may discharge through a vent outlet at 
the mouth of the tap. If the tap is not installed using the Font pedestal, ensure 
the tap body is located so the tap outlet safely drains into the sink bowl area. 

NOTE:

 On startup, the controls take the system through a calibration process 

which causes the unit to over-boil for a period of 90 seconds. Once this mode 
is completed the system reverts back to normal operation.

Lifting

Take care when lifting the Zip HydroTap undersink unit. Some units may 
exceed safe lifting guidelines. If you feel this is beyond your personal 
capabilities, please seek assistance with the lift. The weights of the units are 
marked on the packaging and are given in the table on P6. Do not lift the unit 
by the doors. 

Airflow

The ambient temperatures this unit should operate within are 5ºC -  35ºC. 
Proper air circulation must be provided. The system will operate satisfactorily 
only if the recommended air gaps are provided, these are 65mm min rear 
clearance and 50mm side clearance. An air vent is provided with each unit for 
high usage applications, this must be installed in the top half of the cupboard 
door as a matter of course. An accessory exhaust fan kit is available and when 
supplied should always be fitted to ensure adequate ventilation. Make sure 
that the ventilation grilles of the undersink unit are not obstructed. 

I

ncluded in 

the installation pack are adhesive backed silicon buffers. If air vents are not 
installed in the cupboards housing the HydroTap, the buffers must be placed 
on the inside edge of the cupboard door to create a slight gap  ensuring a 
minimum airflow. Failure to do this may cause the HydroTap to overheat and 
operate inefficiently.

Altitude 

The Zip HydroTap is equipped with a self-calibrating program which caters for 
altitude adjustment.                                                                                                   

Zip Hydrotap undersink assembly.

The appliance must be placed in a 

horizontal position, as shown above.

The power point must be located within 
reach of its cable. The power lead is 
supplied with the plug head removed to 
facilitate ease of fitting to a 13 amp fused 
spur. The appliance must be positioned so 
that the power point is accessible.

Summary of Contents for Commercial HydroTap 86682

Page 1: ...ge 1 of 20 Commercial HydroTap Filtered boiling and chilled drinking water for Commercial kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the follow...

Page 2: ...r counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing...

Page 3: ...adjustment 11 Font Installation Procedure 12 Operating the Tap 13 Child Safety lock 14 Cleaning 14 Setting the Energy Saver Timer 15 Auxiliary Fan Attachment 16 Boiling Water Isolation 16 Set the Hot...

Page 4: ...ake care when lifting the Zip HydroTap undersink unit Some units may exceed safe lifting guidelines If you feel this is beyond your personal capabilities please seek assistance with the lift The weigh...

Page 5: ...ce Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard...

Page 6: ...ace in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the undersink unit to allow for...

Page 7: ...et on the unit For BC120 60 model connect the plastic inlet hose supplied to the cold water inlet on the unit This is located at the rear of the unit Position the Zip HydroTap undersink unit as close...

Page 8: ...ow if required Only choke the flow if it is excessively strong Model B boiling only models Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit...

Page 9: ...jacent surface measure and trim the filter inlet and filter outlet tubes Fit the tubes to their respective inlets and outlets checking to ensure the flow of water corresponds to the direction indicate...

Page 10: ...ane Press the adjust button again to stop the Filter Flush Mode Turn OFF the Filter Flush stop cock and re locate the tube and stop cock in the filter compartment Turning OFF the Filter Flush Mode put...

Page 11: ...it will show the following Hot Temp Lvl Cold Temp Lvl NOTE The temperatures shown are actual not the set temperatures To revert back to the Normal Operation screen press the adjust buttons together ag...

Page 12: ...ixing nut with the Tube Spanner provided in the kit 6 Tighten the securing pin so the Font base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly posit...

Page 13: ...thin its normal specified lifespan Filter Change Light Flashing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the fil...

Page 14: ...ly Safety Lock boiling only models To activate the safety lock go to the LCD display using menu or buttons scroll to the Safety Lock display To turn ON adjust button to turn OFF adjust button After ab...

Page 15: ...Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mode In this mode the unit will go to sleep after a predetermined period of inactivity Press either Menu or Menu button unt...

Page 16: ...mode is active 5 To temporarily de actvate and dispense boiling water press the Safety Lock 3 three times rapidly the LED s will scroll from right to left 3 three times This operation confirms de act...

Page 17: ...f this isolates the water supply 2 Open the left door or on the compact model remove the front cover 3 Relieve system pressure via the filter flush stop cock a quick open and close will do 4 Grasp fil...

Page 18: ...ion Check water supply is on Check to ensure plumbing connection is made Check power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check...

Page 19: ...Hydro Tap Installation and Operating Instructions 86682 March 2012 v1 05 Page 19 of 20 Typical undersink layout 50 50 Fused Spur...

Page 20: ...urned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods...

Reviews: