Page 16 of 20
Hydro Tap Installation and Operating Instructions - 86682 - March 2012 v1.05
Auxiliary Fan Attachment
The HydroTap is equipped with an auxiliary fan connection point on the rear panel close to the
cold water inlet / flex and plug area. The fan kit is available as a spare part. The fan operates
in parallel with the Condenser fan helping to remove heat from the cupboard space. This
fan should be purchased and connected to the HydroTap if the airflow characteristics of the
cupboard space are inadequate for the effective removal of hot air, thereby adversely affecting
the operation of the HydroTap.
The fan can be installed so that it extracts air from, or forces air into the cupboard space,
whichever is the most effective for your installation.
Application of the fan is of paramount importance in situations where the cupboard space
reaches temperatures greater than 35ºC.
The exhaust fan kit must be fitted, when supplied with the appliance.
Note:
The 200/175+ model is supplied with the axillary fan kit
Auxiliary fan
connection
Cold water
connection
Electrical
connections
Boiling Water Isolation
The HydroTap if equipped with an additional safety mode that allows protection against
accidental operation by Infirm or disabled persons.
1. On the LCD scroll through the menu to Hot Isolation.
2. Press adjust
>
to activate.
3. Now go to the Tap Head assembly and press the Safety Lock (3) three times rapidly, the
LED’s will scroll from left to right (3) three times. This operation confirms the activation.
4. This isolates the boiling tap only. The LCD shows isolation mode is active.
5. To temporarily de-actvate and dispense boiling water, press the Safety Lock (3) three
times rapidly, the LED’s will scroll from right to left (3) three times. This operation confirms
de-activation and will temporarily be de-activated. After 30 seconds of no use the unit will
revert to isolation.
6. If permanent de-activation is required, de-activate by scrolling through the menu and
selecting de-activate when Hot isolation Mode is displayed on the screen.
7. The LCD will show Normal Operation.
Set the Hot & Cold water dispensing times
The ability to change the maximum dispensing time for both the Hot and Cold water has been
introduced. The default settings for the maximum dispensing times is 15 secs. The ability to
change both the Hot and Cold dispensing times between 5 and 15 seconds, in increments of 1
sec, is accessible through the Menu screen on the LCD.
Scroll through the Menu until the Dispense Hot screen is displayed, then use the adjust buttons
to set the required dispensing time for the Hot water.
Follow the same procedure to access the Dispense Cold screen.
These instructions must be read in conjunction with the filter fitting instructions supplied with
the high performance filter kit.
Depending on local water quality conditions and usage, the filter may require changing
anywhere from 1000 Litres to 3000 Litres. You may also need to replace the filter if you notice
unpleasant odours or tastes.
To change the pre-set filter life, scroll through the menu to “External Filter Life”, press adjust
>
to reset litre counter. Press adjust
>
and it asks “are you sure”. Press adjust
>
again to lock in
the command.
To Change the external filter:
1. Scroll through the screen menu to “Filter Flush Off” this isolates the water supply.
External Filter Replacement