Hydro Tap Installation and Operating Instructions - 86682 - March 2012 v1.05
In addition to normal tools, the following will be required:
• 35mm diameter sheet metal hole punch for sink tops. (not supplied)
• 35mm diameter hole saw for timber bench tops. (not supplied)
• Nut runner tube spanner (supplied) for fixing tap assembly.
When installing a Font unit:
• For font installation:108mm diameter sheet metal or hole saw to suit surface being cut.
Special Tools Required
These Installation Instructions cover the entire Commercial HydroTap range. Use
the chart on the left to identify the model you are using:
BC = Boiling and Chilled, Filtered,
F = Filtered
B = Boiling only
D
= Disabled lever controls (optional order only)
Note: “+” chiller will continue to dispense water after stated capacity has been
used although this may be at a higher temperature.
BC
Model
160
Cups of
Boiling Water
per Hour
125
Glasses of
Chilled Water
per Hour
Models Covered by These Instructions
Model
Height mm
Depth mm
Width mm
Weight empty kg’s Weight full kg’s
BC120/60+
348
380
385
26
30
BC160/125+
337
430
440
28
35
BC200/175+
395
465
500
29.5
38
B160F
337
323
280
9.5
12
B200F
393
340
310
10
14
Note:
The
Cup
measurement =167ml, the
Glass
measurement = 200ml
• Sufficient space in the cupboard to install the undersink unit in accordance with these Installation Instructions.
A table of dimensions is given above.
NOTE:
Add 65mm to the Depth of the undersink unit to allow for Water and Electrical connections and
ventilation.
• A water supply connection with isolating valve inside the cupboard within reach of the 750 mm flexible connection
and positioned so that the connection point and the stop cock will not be obstructed when the undersink unit is
installed.
• A power supply of 220-240 Volt AC, for connection to the hydrotap via a 13 amp fused spur which must be
accessible after installation.
• This switch must provide all-pole disconnection with a contact separation of at least 3mm, installed in accordance
with IEE wiring regulations.
• A cold water supply with a minimum working pressure of 0.7 bar (70 kPa) dynamic and a maximum working pressure
of 7 bar (700 kPa) connected via an isolation valve. If pressure is likely to exceed 7 bar (700 kPa), install a 3.5 bar (350
kPa) Pressure Limiting Valve.
• The fitting of an air flow vent, cut into the top half of the cupboard door concealing the HydroTap requires a cut size
of approximately 100mm circular, to provide adequate warm air displacement. In installations where high volume
draw-off will occur, the fitting of the accessory exhaust fan is essential.
Important:
Do not proceed with the installation if these requirements are not met.
Installation Requirements