1.
Position the Font template (provided) on the bench area. Ensure the
position you select is within the length of the supply tube and USB
cable fixed to the Tap Head Assembly. These cannot be extended
.
2. Check again for correct positioning. The supply hoses must have
constant fall back to the tank assembly. Cut the holes as shown on the
template.
3. Once holes are cut, locate the Font base in position, from the
underside, lightly tighten the securing rod with the nut and washer
provided.
4. Apply a light smear of silicon sealant to the underside of the black base
ring, this will provide a water tight seal against the Font base when
clamped.
*
Ensure the plastic spacer is correctly located under the
Font.
5. Now take the Tap Head Assembly. Feed the hoses and USB cable
through the Font base, then through the plastic spacer that sits under
the font base but on the bench top. This stops warping of the base
plate. Ensure the Tap spout is directly centred over the Font drain. Fit
the “Spider Clamp”, nut and washer onto the “All Thread”. Have all
the supply tubes and USB cable located evenly between the “Spider
Clamp” legs. When satisfied with the positioning, tighten the fixing nut
with the Tube Spanner provided in the kit.
6. Tighten the securing pin so the Font base is flush with the bench top.
NOTE:
The fixing nut above the drain elbow can be loosened to
correctly position the direction of the elbow. Ensure when the
re-positioning is complete the nut is re-tightened to ensure a water
tight seal.
7. Connect a drain hose (22mm ID) from the Font base outlet elbow to the
closest drain trap spigot available. If a spigot is not available use the
snap on spigot and worm drive clamps supplied in the kit.
8. Ensure the positioning of the snap-on spigot is on the “sink” side of
the trap and not the “waste” side. Once positioned, a hole (13mm ID)
will need to be drilled to provide waste access to the drain line. The
snap-on unit will require suitable sealant to keep it water tight against
the waste pipe. Finish by fitting the worm drive clamps tightly on either
side of the spigot and fitting worm drive clamps to either end of the
drain hose. The drain hose from the Font must have constant fall
9. Connect the Tap head Assembly supply hoses and vent as per the
instructions contained in the installation procedure section of this
document.
Font Installation Procedure
Tap assy
hole 35mm
Hole required for Font
recess 108mm
Fixing stud
Drain elbow
View from underside
Cut a 10mm
slot for stud
Note:
A stainless steel washer
is supplied to go in between the
Spider Clamp and the underside
of the worktop. See location as
shown.
*