Trouble Shooting 

Symptom 

 

     Possible Cause 

 

    Solution

No LED display, no tap head 
lights or, no water when tap 
levers are operated.

No water flow.

 

 

Slow water recovery after 
use. 

Water not hot.

 

Water not chilled.

No power.

Plug is not located in power 
socket.

Tap loom is not connected to 
HydroTap unit.

Possible internal fault.

Program in OFF cycle

Water supply isolated.

Water supply not connected.

Power supply not connected. 

Tap loom is not connected to 
HydroTap unit.

Possible internal fault.

Program in OFF cycle.

Filter may require replacement. 
 

Unit is in Sleep Mode.

Unit has just come out of OFF 
cycle.

Possible internal fault.

Excessive use, unit refilling or 
chilling down to temperature.

Possible internal fault.

Check power supply.

Ensure power plug is correctly fitted and switch is 
turned ON.

Check loom connection. 

Contact local Zip Service Provider.

Check LCD for information.

Check water supply is on.

Check to ensure plumbing connection is made.

Check power plug is correctly fitted and switch is 
turned on.

Check for loom connection 

Contact local Zip Service Provider.

Check LCD for information.

Check filter usage on LCD screen, if “filter 
change” is displayed follow instructions            
on page 16, 17 & 18.

Touch Hot lever and wait for Red LED to stop 
flashing.

Wait for Red LED to stop flashing.

Contact local Zip Service Provider.

Wait for Blue LED to stop flashing. 

Contact local Zip Service Provider.

Alternating  display  messages:       More than one fault identified 

at the same time

Record the number and type of faults

Contact local Zip Service Provider

Warning:

 

If the Zip HydroTap is switched off for a long period of time    (e.g. 

More than a weekend), run water through the chilled water outlet for at least 5 
minutes before consumption.

15. Scroll through the menu to “Filter Used (Days)”, press adjust 

>

 to reset 

the timer. Press adjust 

>

 and it asks “are you sure”. Press adjust 

>

 again 

to lock in the command. After approx 10 seconds it will default to the 
selected mode.

16. Close the door to secure the appliance. 

 

 

        

Internal Filter Replacement 

(continued) 

Summary of Contents for Commercial HydroTap 86682

Page 1: ...ge 1 of 20 Commercial HydroTap Filtered boiling and chilled drinking water for Commercial kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the follow...

Page 2: ...r counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing...

Page 3: ...adjustment 11 Font Installation Procedure 12 Operating the Tap 13 Child Safety lock 14 Cleaning 14 Setting the Energy Saver Timer 15 Auxiliary Fan Attachment 16 Boiling Water Isolation 16 Set the Hot...

Page 4: ...ake care when lifting the Zip HydroTap undersink unit Some units may exceed safe lifting guidelines If you feel this is beyond your personal capabilities please seek assistance with the lift The weigh...

Page 5: ...ce Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard...

Page 6: ...ace in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the undersink unit to allow for...

Page 7: ...et on the unit For BC120 60 model connect the plastic inlet hose supplied to the cold water inlet on the unit This is located at the rear of the unit Position the Zip HydroTap undersink unit as close...

Page 8: ...ow if required Only choke the flow if it is excessively strong Model B boiling only models Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit...

Page 9: ...jacent surface measure and trim the filter inlet and filter outlet tubes Fit the tubes to their respective inlets and outlets checking to ensure the flow of water corresponds to the direction indicate...

Page 10: ...ane Press the adjust button again to stop the Filter Flush Mode Turn OFF the Filter Flush stop cock and re locate the tube and stop cock in the filter compartment Turning OFF the Filter Flush Mode put...

Page 11: ...it will show the following Hot Temp Lvl Cold Temp Lvl NOTE The temperatures shown are actual not the set temperatures To revert back to the Normal Operation screen press the adjust buttons together ag...

Page 12: ...ixing nut with the Tube Spanner provided in the kit 6 Tighten the securing pin so the Font base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly posit...

Page 13: ...thin its normal specified lifespan Filter Change Light Flashing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the fil...

Page 14: ...ly Safety Lock boiling only models To activate the safety lock go to the LCD display using menu or buttons scroll to the Safety Lock display To turn ON adjust button to turn OFF adjust button After ab...

Page 15: ...Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mode In this mode the unit will go to sleep after a predetermined period of inactivity Press either Menu or Menu button unt...

Page 16: ...mode is active 5 To temporarily de actvate and dispense boiling water press the Safety Lock 3 three times rapidly the LED s will scroll from right to left 3 three times This operation confirms de act...

Page 17: ...f this isolates the water supply 2 Open the left door or on the compact model remove the front cover 3 Relieve system pressure via the filter flush stop cock a quick open and close will do 4 Grasp fil...

Page 18: ...ion Check water supply is on Check to ensure plumbing connection is made Check power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check...

Page 19: ...Hydro Tap Installation and Operating Instructions 86682 March 2012 v1 05 Page 19 of 20 Typical undersink layout 50 50 Fused Spur...

Page 20: ...urned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods...

Reviews: