Normal Operation

Set Time 

To change time, press either Menu 

>

 or Menu 

>

 button until Set Time is on the 

display screen. Press 

>

 Adjust button to increase time or 

>

 Adjust button to decrease 

time. Time increases or decreases in increments of one minute. Hold the Adjust buttons 

down for rapid increases or decreases. The time will be displayed in 24Hr mode.

Set Day 

Press either Menu 

>

 or Menu 

>

 button until Set Day is displayed. 

Press 

>

 Adjust or 

>

 Adjust to select day.

Filter Life 

( Factory set at 6000 Ltrs )

Press either Menu 

>

 or Menu 

>

 button until Filter Life is displayed. 

Press 

>

 Adjust button to increase Filter Life or 

>

 Adjust button to decrease Filter Life. 

Filter Life increases in 1000 Ltr increments to a maximum of 10000 Ltrs.

Reset Litres Filtered 

This function is to reset the Filter Change display after a filter has reached the end of 
its life (refer to “Replace Filter Instructions” section of this document).

Press either Menu 

>

 or Menu 

>

 button until “Litres Filtered” is displayed. Press 

>

 

Adjust once and “Reset Counter” will be displayed, press 

>

 Adjust button once and 

“Are You Sure” will be displayed.

Press 

>

 Adjust once and “Litres Filtered” will be reset to 0.

Activating Sleep Mode 

This mode allows the HydroTap to go into Energy Saving mode. In this mode the unit 
will go to “sleep” after a predetermined period of inactivity. Press either Menu 

>

 or 

Menu 

>

 button until “Sleep Mode” is displayed.  

Press 

>

 Adjust once to select

Option 1:

 Sleep to 65ºC after 2 hours of NO USE 

Press 

>

 Adjust once to select

Option 2:

 Auto OFF after 2 hours of NO USE. 

When the period of inactivity passes, the display will show “Sleep Mode”. During the 
“Sleep Mode” the Red LED on top of the tap lever will flash slowly. 

Sleep to OFF means the Boiling and Chilled circuits will be switched OFF

To de-activate the sleep mode, momentarily operate the Hot lever and then allow 
sufficient time for the water to reach the set temperature

Activating 7 Day Timer On / Off Mode 

Press the Menu 

>

 or Menu 

>

 button until “Monday On” is displayed. To set the time 

for the unit to turn on press 

>

 Adjust button until required time is reached. 

To set the time for the unit to turn Off press Menu 

>

 button once and “Monday Off” 

will be displayed. Now press 

>

 Adjust until required time is reached.

If each individual day is to have an “On / Off” time, these steps need to be repeated for 
each day and for each On / Off time.

Note:

The Hydrotap may be 
temporarily activated by 
operating the HydroTap 
levers, the unit will go into 
normal operation and then 
remain in an “ON” cycle, 
until the next “OFF” cycle.

Setting the Energy Saver Timer 

(products with this feature only) 

Summary of Contents for Commercial HydroTap 86682

Page 1: ...ge 1 of 20 Commercial HydroTap Filtered boiling and chilled drinking water for Commercial kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the follow...

Page 2: ...r counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing...

Page 3: ...adjustment 11 Font Installation Procedure 12 Operating the Tap 13 Child Safety lock 14 Cleaning 14 Setting the Energy Saver Timer 15 Auxiliary Fan Attachment 16 Boiling Water Isolation 16 Set the Hot...

Page 4: ...ake care when lifting the Zip HydroTap undersink unit Some units may exceed safe lifting guidelines If you feel this is beyond your personal capabilities please seek assistance with the lift The weigh...

Page 5: ...ce Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard...

Page 6: ...ace in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the undersink unit to allow for...

Page 7: ...et on the unit For BC120 60 model connect the plastic inlet hose supplied to the cold water inlet on the unit This is located at the rear of the unit Position the Zip HydroTap undersink unit as close...

Page 8: ...ow if required Only choke the flow if it is excessively strong Model B boiling only models Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit...

Page 9: ...jacent surface measure and trim the filter inlet and filter outlet tubes Fit the tubes to their respective inlets and outlets checking to ensure the flow of water corresponds to the direction indicate...

Page 10: ...ane Press the adjust button again to stop the Filter Flush Mode Turn OFF the Filter Flush stop cock and re locate the tube and stop cock in the filter compartment Turning OFF the Filter Flush Mode put...

Page 11: ...it will show the following Hot Temp Lvl Cold Temp Lvl NOTE The temperatures shown are actual not the set temperatures To revert back to the Normal Operation screen press the adjust buttons together ag...

Page 12: ...ixing nut with the Tube Spanner provided in the kit 6 Tighten the securing pin so the Font base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly posit...

Page 13: ...thin its normal specified lifespan Filter Change Light Flashing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the fil...

Page 14: ...ly Safety Lock boiling only models To activate the safety lock go to the LCD display using menu or buttons scroll to the Safety Lock display To turn ON adjust button to turn OFF adjust button After ab...

Page 15: ...Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mode In this mode the unit will go to sleep after a predetermined period of inactivity Press either Menu or Menu button unt...

Page 16: ...mode is active 5 To temporarily de actvate and dispense boiling water press the Safety Lock 3 three times rapidly the LED s will scroll from right to left 3 three times This operation confirms de act...

Page 17: ...f this isolates the water supply 2 Open the left door or on the compact model remove the front cover 3 Relieve system pressure via the filter flush stop cock a quick open and close will do 4 Grasp fil...

Page 18: ...ion Check water supply is on Check to ensure plumbing connection is made Check power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check...

Page 19: ...Hydro Tap Installation and Operating Instructions 86682 March 2012 v1 05 Page 19 of 20 Typical undersink layout 50 50 Fused Spur...

Page 20: ...urned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods...