Zip Commercial HydroTap 86682 Installation And Operating Instructions Manual Download Page 13

Hydro Tap Installation and Operating Instructions - 86682 - March 2012 v1.05                                        Page 13 of 20

Blue Chilled Water Light

On all the time:  

This indicates that the temperature of the chilled water is within the 
usable temperature range.

Flashing slowly : 

This indicates that the chilled water is not at the right temperature. Wait 
up to 20 minutes. When the chilled water is at the right temperature, the 
light will stop flashing. Note: The Zip HydroTap is designed to dispense 
chilled water in the temperature range 5°C to 15°C for BC120/60+ or 
5°C  to  10°C  for  BC160/125+  and  BC200/175+  depending  on  settings.                                                                   

During heavy usage, the temperature can rise out of this range.                                                                                                                               

Red Boiling Water Light 

On all the time: 

This indicates that the boiling water is ready. 

Flashing slowly : 

This indicates that the boiling water is below usable temperature.

 

Filter light

Filter Change Light Off: 

This  indicates  the  filter  is  operating  within  its  normal  specified  lifespan.                                                                                                  

Filter Change Light Flashing slowly :

The light will flash slowly when the filter is due for replacement and the 
LCD will show “Filter Change”. Refer to  “Replacing the filter” section of 
this document. (see P16 & P17). 

Lever Operation

Boiling Water Lever (with safety disengaged)                                                                                 

Depressing the “Red” lever allows dispensing of Boiling water.                       
Pulling up the Red lever allows the tap to operate in a “no-touch” mode. 
Water will flow

 

from between 5 and 15 seconds (This is user adjustable). 

To reset, return the handle to the “Off” position and repeat the step. The 
lever has to be manually returned to the “Off” position.

Chilled Water Lever                                                                                  

Depressing the “Blue” lever allows dispensing of Chilled water.                        
Pulling up the Blue lever allows the tap to operate in a “no-touch” 
mode. Water will flow from between 5 and 15 seconds (This is user 
adjustable). To reset, return the handle to the “Off” position and repeat 
the step. The lever has to be manually returned to the “Off” position.

 Operating the Tap

Note:

 On the Boiling only models the Chilled 

LED is blank.

Boiling

Chilled

Filter Change

Press or pull lever

Summary of Contents for Commercial HydroTap 86682

Page 1: ...ge 1 of 20 Commercial HydroTap Filtered boiling and chilled drinking water for Commercial kitchens and tea rooms Installation and Operating Instructions This Installation Instruction covers the follow...

Page 2: ...r counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing...

Page 3: ...adjustment 11 Font Installation Procedure 12 Operating the Tap 13 Child Safety lock 14 Cleaning 14 Setting the Energy Saver Timer 15 Auxiliary Fan Attachment 16 Boiling Water Isolation 16 Set the Hot...

Page 4: ...ake care when lifting the Zip HydroTap undersink unit Some units may exceed safe lifting guidelines If you feel this is beyond your personal capabilities please seek assistance with the lift The weigh...

Page 5: ...ce Provider Frost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard...

Page 6: ...ace in the cupboard to install the undersink unit in accordance with these Installation Instructions A table of dimensions is given above NOTE Add 65mm to the Depth of the undersink unit to allow for...

Page 7: ...et on the unit For BC120 60 model connect the plastic inlet hose supplied to the cold water inlet on the unit This is located at the rear of the unit Position the Zip HydroTap undersink unit as close...

Page 8: ...ow if required Only choke the flow if it is excessively strong Model B boiling only models Measure and trim the red marked tube and connect it to the hot water outlet on the top of the undersink unit...

Page 9: ...jacent surface measure and trim the filter inlet and filter outlet tubes Fit the tubes to their respective inlets and outlets checking to ensure the flow of water corresponds to the direction indicate...

Page 10: ...ane Press the adjust button again to stop the Filter Flush Mode Turn OFF the Filter Flush stop cock and re locate the tube and stop cock in the filter compartment Turning OFF the Filter Flush Mode put...

Page 11: ...it will show the following Hot Temp Lvl Cold Temp Lvl NOTE The temperatures shown are actual not the set temperatures To revert back to the Normal Operation screen press the adjust buttons together ag...

Page 12: ...ixing nut with the Tube Spanner provided in the kit 6 Tighten the securing pin so the Font base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly posit...

Page 13: ...thin its normal specified lifespan Filter Change Light Flashing slowly The light will flash slowly when the filter is due for replacement and the LCD will show Filter Change Refer to Replacing the fil...

Page 14: ...ly Safety Lock boiling only models To activate the safety lock go to the LCD display using menu or buttons scroll to the Safety Lock display To turn ON adjust button to turn OFF adjust button After ab...

Page 15: ...Activating Sleep Mode This mode allows the HydroTap to go into Energy Saving mode In this mode the unit will go to sleep after a predetermined period of inactivity Press either Menu or Menu button unt...

Page 16: ...mode is active 5 To temporarily de actvate and dispense boiling water press the Safety Lock 3 three times rapidly the LED s will scroll from right to left 3 three times This operation confirms de act...

Page 17: ...f this isolates the water supply 2 Open the left door or on the compact model remove the front cover 3 Relieve system pressure via the filter flush stop cock a quick open and close will do 4 Grasp fil...

Page 18: ...ion Check water supply is on Check to ensure plumbing connection is made Check power plug is correctly fitted and switch is turned on Check for loom connection Contact local Zip Service Provider Check...

Page 19: ...Hydro Tap Installation and Operating Instructions 86682 March 2012 v1 05 Page 19 of 20 Typical undersink layout 50 50 Fused Spur...

Page 20: ...urned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods...

Reviews: