Section 10.0
MAN 06–0017H
ZIEHM QUANTUM
User’s Manual
Page 144 of 220
WARNING:
The user operator should use only medical grade CD and DVD disk as they have been
checked for flaws in the media and will be more successful in completing a store to the
disk.
Standard off the shelf CD and DVD disks may fail to write on occasion or may lose or
have defective media that will cause patient records to be lost when using these disks.
Some Media types may perform all the steps but fail to complete the TOC operations,
Make sure you check all disk in a PC to make sure data has been transferred before
deleting any images from the image system.
Ziehm Imaging, Inc.
is not responsible for lose of patient information/data or poor
performance of the export function if common, non-medical grade DVD and CD disk are
used.
WARNING:
The
ZIEHM QUANTUM
is not to be used as a long term “Archiving Device”, its
primary use is in capturing and storing for limited time patient information and should
not be considered a mass storage or image server for patient data.
Ziehm Imaging, Inc.
recommends the owner operator make backs of up all images for
patients using achievable media for long term image storage.
This could be Archival CD and DVD’s or by using Optional DICOM interface or by
using USB memory devices to transfer the images to a PAC’S image server or to other
computer systems having Archiving capabilities.
WARNING:
The
Ziehm Imaging, Inc.
recommends storing images to the USB device during the
procedure, transferring patient images after the procedure or transferring images at least
at the end of each day to prevent loss of these important medical records.
NOTE:
When exporting images to any outside media or devices (DICOM server, USB device,
and DVD/CD disk or video port, the system provides a date of export on image as a
means to identify when images were exported from the device.
10.10.1
OVERVIEW OF THE USB AND DVD EXPORT FUNCTIONS:
USB 2.0 data port is provided for the user so they may use simple USB memory devices such as
USB thumb drives USB peripheral hard drives that are not direct drive devices.
The USB port is located on the side o the Mobile C-arm directly in blow the control keyboard.
The USB port will allow the user/operator to transfer images from the c-arm to another computer
in several image formats. (JPEG, TIFF, BMP for still images and AVI and DICOM media for
motion images (Cine/DSA).
You must first select the LOG IN button and log into the system to activate the USB memory
Summary of Contents for QUANTUM
Page 1: ...ZIEHM QUANTUM USER S MANUAL...
Page 2: ...Table of Contents MAN 06 0017H ZIEHM QUANTUM User s Manual Page 2 of 220...
Page 10: ...About this Manual MAN 06 0017H ZIEHM QUANTUM User s Manual Page 10 of 220...
Page 12: ...About this Manual MAN 06 0017H ZIEHM QUANTUM User s Manual Page 12 of 220...
Page 71: ...Section 6 0 MAN 06 0017H ZIEHM QUANTUM User s Manual Page 71 of 220...
Page 96: ...Section 7 0 MAN 06 0017H ZIEHM QUANTUM User s Manual Page 96 of 220...
Page 132: ...Section 9 0 MAN 06 0017H ZIEHM QUANTUM User s Manual Page 132 of 220...
Page 180: ...Section 11 0 MAN 06 0017H ZIEHM QUANTUM User s Manual Page 180 of 220...
Page 196: ...Section 12 0 MAN 06 0017H ZIEHM QUANTUM User s Manual Page 196 of 220...
Page 202: ...Section 14 0 MAN 06 0017H ZIEHM QUANTUM User s Manual Page 202 of 220...