12.2.2
Evacuation through UPS with minimum power
Information - Evacuation through UPS with minimum power
•
Load-dependent starting, cannot be optimized
•
Evacuation only possible in the direction of the pulling load
•
Positioning is carried out load dependent; that means step formation could occur.
Calculation of the UPS
The required UPS performance consists of the following:
Electronic frequency inverter power consumption
+ Control systempower consumption
+ Electromechanical brakes power consumption
+ Other consumers (car light,
…
) power consumption
+ Motor power consumption for UPS operation with reduced power (ask
motor manufacturer)
=
Real power UPS [W]
Information
The shaft ef
fi
ciency has a decisive in
fl
uence on the required power of the UPS performance.
12.2.3
Parameterisation
(1) The following prerequisites must be present:
The direction of travel of the car is downwards with
Standard
DCP
24V signal on input con
fi
gured to
"RV2"
Command byte 1, Bit 4 has 1-sig-
nal
Detection of voltage drop
Con
fi
gure digital input in the
Control system
menu to
PARA2
.
Control
|
-
"
f_I08
PARA2
|
-
"
PARA2
Function I_08
In case of a voltage drop (power failure) the inverter is informed by activating the congured input with
24 VDC that a switchover must be made to parameterset 2.
(3) Inform the open loop control about the permissible direction of travel (optional):
Standard
DCP
Con
fi
gure digital output in the
Control system
menu to
Evac. Dir.
Status byte 2, Bit 2 = 0
R
Car is lighter than coun-
terweight
Evacuation trip will be carried out upwards!
Status byte 2, Bit 2 = 1
R
Car is heavier than
counterweight
Evacuation trip will be carried out downwards!
Control
|
-
"
f_O4
Evac.Dir
|
-
"
Evac.Dir
Function O4
Contact open
R
Car is lighter than counterweight
Evacuation trip will be carried out upwards!
Output closed
R
Car is heavier than counter-
weight
Evacuation trip will be carried out downwards!
Original operating instructions
ZETADYN 3C
Emergency evacuation
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
127/204