CAN Error Info------
16
Err act. Last:No Err
Rec Tra Warn Pas off
0 0 0 0 0
page 16: CAN Error information
Information about telegram errors in CANopen lift operation
Line 2 (from left to right):
Error status
Load: Fault which last occurred
Displayed text:
Meaning
Error status
"Err act."
"Warning"
"Err pass"
"Bus off"
Error active
Warning
Error passive
Bus off
Load: Fault which last
occurred
"No Err"
"Stuff"
"Form"
"ACK"
"Bit(r)"
"Bit(d)"
"CRC"
no error
Stuf
fi
ng Error
Form Error
Acknowledge Error
Bit Error (Recessive Level was output but
Dominant Level detected)
Bit Error (Dominant Level was output but
Recessive Level detected)
CRC Error
Line 3 and 4:
Rec: Number of receive errors
Tra: Number of transmit errors
Warn: Indication how often the frequency inverter switched to the warning status
Pas: Indication how often the frequency inverter switched to the error passive status
off: Indication how often the frequency inverter switched to the bus off status
CAN Calib. 1------ -
17
AbsEncmm: 5358
Mo 4169
Offs:13081A/M 1.28
Page 17: CAN Calib.
Calibration
Lines 2 - 4:
For calibrating the distances which were sent by the motor encoder and the shaft encoder.
A+R - - - - - - - - - - - -
18
0.62 0.62 m/s3
0.50 0.50 m/s2
0.62 0.50m/s3
Page 18: A&R
Display of con
fi
gured values for:
•
Acceleration
•
Rampdown time
dependent on the operating curve of a normal ride
Line 2:
upper round off of the acceleration in m/s
³
upper round off of the deceleration in m/s
³
Line 3:
Acceleration in m/s
³
Deceleration in m/s
³
Line 4:
lower round off of the acceleration in m/s
³
lower round off of the deceleration in m/s
³
Original operating instructions
ZETADYN 3C
Parameter list
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
105/204