background image

 
 

                                                                                                                     

                                                                                                                                                          Smart+ 

User’s  Manual  V1.04.04 

 

 

54

 

                                                  FM07I4A

 

If  users  can’t  find  proper  color  in  the  Color  dialog  box,  they  can  click  the  “Define  Custom  Colors”  button,  the 

following color box will appear. Then users can select the color in the color box, or pull the small triangle to change the 

lightness if necessary. Then click “Add to Custom Colors”, the selected color will be in the Custom Colors box. 

 

If users want to change the waveform background color, click the color button; then in the popped out color dialog box, 

they can choose one color, for example, white. The background color will change to white. 

 

After color changed: 

Summary of Contents for LAP-C(16032)

Page 1: ......

Page 2: ...s 15 1 5 6 Patents Introduction 15 1 6 System Requirements 17 1 7 Device Maintenance and Safety 18 2 Installation 20 2 1 Software Installation 21 2 2 Hardware Installation 23 2 3 Tips and Advice 24 3...

Page 3: ...ific Bus Data Display 99 4 18 Signal Activity 100 4 19 Navigator 102 4 20 Packet List 103 4 21 Statistic 107 4 22 Memory View 110 4 23 Trace Format 113 4 24 Protocol Decoder 114 5 FAQ 117 5 1 Hardware...

Page 4: ...es of Zeroplus Logic Analyzer 1 1 Welcome choosing the product of Zeroplus Technology 1 2 Package Contents 1 3 Introduction 1 4 Specifications 1 5 Special Functions and Patents Introduction 1 6 System...

Page 5: ...trical motor and personal studios This Smart software supports LAP C and LAP D series Note No further notice to you if any modification occurs Please refer to the software to avoid any inconformity 1...

Page 6: ...sting Cable Fig 1 3 Probe differentiated by the model Fig 1 4 USB Cable Fig 1 5 Quick Start Guide Fig 1 6 Driver CD Fig 1 7 1 Pin External Clock Cable White Fig 1 8 2 Pin Ground Cable Black Models LAP...

Page 7: ...cts Fig 1 9 Logic Analyzer Fig 1 10 Testing Cable Fig 1 11 Probe Fig 1 12 USB Cable Fig 1 13 Quick Start Guide Fig 1 14 Driver CD Fig 1 15 BNC Cable Fig 1 16 AC Power Line Fig 1 17 Carry on Bag Fig 1...

Page 8: ...Smart User s Manual V1 04 04 8 FM07I4A 1 3 Introduction Description for LAP C Series Models The USB connection supply the power...

Page 9: ...LAP D ports Refer to the table 1 1 for the detailed port names Table 1 1 List of available channels Back view of LAP D ports Refer to the table 1 2 for the detailed port names Models LAP D 32064M LAP...

Page 10: ...t will send out a 3 3V Rising Edge Falling Edge Status signal External Port Expansion Ports Pin NO Function Description Pin NO Function Description 1 3 3V 2 Ground 3 Trigger Status 4 5 N A 6 7 Externa...

Page 11: ...its 4Mbits Memory Per Channel 32 K bits Max 8Mbits for Compression 64 K bits Max 16Mbits for Compression 128 K bits Max 32Mbits for Compression Trigger Trigger Channel 16CH Trigger Condition Pattern E...

Page 12: ...Signal Filter and Delay Yes Compression Max 512Mbits Max 32Mbits Max 512Mbits Waveform Width Display Yes Trigger Page 8192 Pages Double Mode Yes Trigger Mark Yes Latch Function Yes Data Contrast Yes...

Page 13: ...ast Option Yes Multi stacked Function Yes Protocol Analyzer Trigger Option Free Safety Certification FCC CE WEEE RoHS Model LAP D 32512M Channel Mode 32CH 16CH 8CH Interface USB 2 0 1 1 Operating Syst...

Page 14: ...e 5V 5V Trigger Voltage Accuracy 0 1V Memory 2Gbits Memory Per Channel 64 Mbits 128 Mbits 256 Mbits Internal Clock Asynchronous 400MHz 800MHz 1 6GHz External Clock Synchronous 200MHz Trigger Condition...

Page 15: ...ange and along with LAP D multi level trigger function this function can set hardware trigger for many serial signals so more waveform can be captured 1 5 6 Patents Introduction Data Compression Paten...

Page 16: ...ta in a list with which analyzing the relation between each packet becomes much easy Memory Analyzer Display the packet data that analyzed by the Smart bus decoding module in the memory map way which...

Page 17: ...64 bit version Windows NT 4 0 Workstation Server Service Pack 6 Windows Server 2003 Hardware System Requirements for LAP C and LAP D Hardware Name Lowest Configuration Recommended Configuration CPU 1G...

Page 18: ...e harsh chemicals or cleaners containing substances such as benzene toluene xylene or acetone Electrical Specifications LAP C Series Item Minimum Typical Maximum Working Voltage DC 4 5 V DC 5 0 V DC 5...

Page 19: ...nly non conductive pollution occurs But temporary conductivity caused by the occasional condensation must be kept in mind Pollution Level 3 Conductive pollution occurs or dry non conductive pollution...

Page 20: ...Smart User s Manual V1 04 04 20 FM07I4A 2 Installation 2 1 Software Installation 2 2 Hardware Installation 2 3 Tips and Advice...

Page 21: ...the Logic Analyzer can work normally STEP 3 If the CD can t auto play click Start Run and input D set exe if the CD ROM is D in the input box then click Next Make sure the LA connects with the PC by U...

Page 22: ...ish to complete the installation The Finish page reminds users to restart the computer now or later recommend to select Yes I want to restart my computer now STEP 6 Once the Logic Analyzer is power on...

Page 23: ...07I4A 2 2 Hardware Installation Connect the B type connector of the attached USB connect line with the B type socket of Logic Analyzer and the A type with the A type socket of computer Keep the power...

Page 24: ...metal prongs Insert the metal prongs into the metal connector of device under test and release to let them to grip the metal connector Fig 2 3 4 If the internet is available the Logic Analyzer will c...

Page 25: ...Smart User s Manual V1 04 04 25 FM07I4A 3 Users Interface 3 1 User Interface 3 2 Main Menu 3 3 Right Key Menu 3 4 Common Tools...

Page 26: ...sily The corresponding shortcut key information will appear when users move the cursor to one icon For example the shortcut key of New button is Ctrl N so when users place the cursor on the icon New C...

Page 27: ...uler Time vector in the waveform view area F Channel Column Edit channel names G Trigger Column Set the signal trigger conditions fast and intuitively H Filter Column Set the signal filter conditions...

Page 28: ...suitable for D Series by clicking the top right icon Trigger Position Users can drag the cursor or roll the roller to adjust Composite Panel 1 Basic tool Normal and Hand Modes can be switched 2 Wavef...

Page 29: ...asn t ever been saved it will be saved as a new file in the format of lap or alc Save As Save the current file as a new file in the format of lap or alc Export Export the Waveform Packet List or Memor...

Page 30: ...function is activated the RAM size will be up to 256K For models of 32 channels channels 1 16 will use the RAM size of channels 17 32 to capture large data Models of 16 channels have no such limitati...

Page 31: ...e Select a waveform range to analyze by adjusting the position of Ds and Dp Bars Add Add bar with user defined quantity and color The fixed order is A0 A9 B0 B9 and the like 250 bars can be added at m...

Page 32: ...lacing the cursor on the bar and dragging can move the bar This function is unavailable in Listing Window Hand Move the data in the Waveform State List area by dragging the left key Placing the cursor...

Page 33: ...Smart User s Manual V1 04 04 33 FM07I4A State List Display logic status Logic 0 signal is displayed as 0 logic 1 signal is displayed as 1 unknown signal is displayed as U see below image...

Page 34: ...f each channel Navigator The Navigator is under the waveform view area it displays the captured data waveform of four channels right click to select channels Frame dragging in the Navigator can select...

Page 35: ...display it on either screen Current opened window is indicated on the bottom 3 2 7 Help H Menu Help Open the Help file of LA to get the detailed information about how to use this software Hot Keys Op...

Page 36: ...mal signed Hexadecimal ASCII Gray Code and Complement The default is Hexadecimal Image Decode It is used to analyze the data format of Protocol Analyzer and display its decoded data in image Protocol...

Page 37: ...er outline and analog waveform line This option is disabled in Listing Window Add Bar When the cursor is in the waveform view area press right key and select Add Bar to add a new bar with the order of...

Page 38: ...cursor position B Bar Place B Bar in the cursor position Ds Bar Place Ds Bar in the cursor position It is available after Select an Analytic Range is activated Dp Bar Place Dp Bar in the cursor posit...

Page 39: ...te a new document Hide Open an existing document Single Analog Display Save the current file Mixed Analog Display Save the file as another new file Normal Save Settings Hand Export the waveform Zoom O...

Page 40: ...DSO stacked Settings Navigator Select an Analytic Range Bus Packing List Noise Filter Statistics Window Data Contrast Memory Analyzer Previous Difference All Screen Display Next Difference First Scree...

Page 41: ...and Find Setup 4 8 External Trigger 4 9 Signal Filter Setup 4 10 Add Channel Bus Setup 4 11 Connect Multiple smart 4 12 Connect to DSO 4 13 Noise Filter Setup 4 14 Files Comparison 4 15 Math Operatio...

Page 42: ...rmation of selected file The software supports formats of als alc and lap if opens als or alc file it will automatically convert them to lap file For models in same series high level ones could open t...

Page 43: ...can save the summary information so they can preview it before opening the file next time File could be saved in format of lap and alc If a file is saved in alc format then it only could be opened by...

Page 44: ...ge Output Data By Timestamp Export the data with timeline order By Channel Bus Export the data with channel order Channels Buses All channels and buses Export data of Channel Bus and Protocol Decoder...

Page 45: ...ange to export The range can be First data Last data T Bar A Bar B Bar Page and User Defined Set by time or sampling site Limit the number of lines per export file 1 000 60 000 After activated the num...

Page 46: ...export file 100 5 000 After activated the max quantity of line of each exported file can be set For example if users input 100 that means the packet quantity is 1 100 in each exported file Export Set...

Page 47: ...Smart User s Manual V1 04 04 47 FM07I4A Users can export and save the data of the Memory Analyzer List Window as txt CSV or Bin format 4 3 Screen Capture...

Page 48: ...er picture editing software Ms Paint Open the captured region by Ms Paint Capture Region Full Screen Capture the full screen Select Region Capture the selected region Note Input note that will be disp...

Page 49: ...Select the Printer and click Properties to set the settings must be saved Print range All Print all data in the waveform view area Pages Print pages in a specified range Current Page Print the data o...

Page 50: ...Options For the question When pressing Stop during sampling users can select Show present acquisition or Show newly acquired data the default is Show present acquisition Packet Names Display the packe...

Page 51: ...s automatically when hardware linked Show the notice about expiration of product key Protocol analyzers or particular functions of main program that expire in 3 days would be displayed in purple and e...

Page 52: ...ons are not selected by default Dictates can classified into various groups Item The icons belong to the selected group will be selected Autohide The toolbar will hide if the cursor is out of its area...

Page 53: ...Make the waveform view area be black and white Contrast After the background is altered the color of related items will change to the contrast color automatically Click the color button of any item t...

Page 54: ...t the color in the color box or pull the small triangle to change the lightness if necessary Then click Add to Custom Colors the selected color will be in the Custom Colors box If users want to change...

Page 55: ...Smart User s Manual V1 04 04 55 FM07I4A If users want to change the color of sampling position they could click the color block of Sampling point marks...

Page 56: ...Smart User s Manual V1 04 04 56 FM07I4A Before color changed the sampling position is yellow After changed the sampling position is red...

Page 57: ...Smart User s Manual V1 04 04 57 FM07I4A 4 5 5 Waveform...

Page 58: ...t show values 1 Don t show values The waveform will be displayed without the time and data 2 Frequency The waveform will be displayed with the frequency In the Frequency the frequency of complete wave...

Page 59: ...24 26 28 30 40 50 60 70 80 90 and 100 the default is 26 Font Size Set the font size Users can input the value between 6 and 60 or select the value from the pulldown menu which including 8 9 10 12 14...

Page 60: ...dle of waveform view area automatically when the trigger condition is met 4 5 6 Hot Keys Commands Select the Command to change its shortcut key Select New Hot Keys Input new shortcut key in the editin...

Page 61: ...ay the first file after the sampling ends Note If the Save files under new names and is not activated Keep time from first save increment version number only and Update time and increment version numb...

Page 62: ...uency range is 0 001Hz 200MHz For models of 16032 and 16064 their external sampling frequency is between 0 001Hz and 75MHz and between 0 001Hz and 200MHz for LAP D Series Trigger Interval The time ran...

Page 63: ...age as the trigger condition Clear Trigger Condition Clear the trigger settings of the current page and restore to the original status Channel Parameter Each channel can be set as Don t Care Low Level...

Page 64: ...or close the level Data Width The time width of level condition the Min value is 1 clock the Max value is 4294967295 clocks Interval Time It is the time width ignored between levels uses can input th...

Page 65: ...packet Min Only when condition is In Range Not Range or the Min value can be set Max Only when condition is In Range or Not In Range the Max value can be set If the condition is String the interface w...

Page 66: ...default Trigger Page After set the Trigger Position or Trigger Count users can set the Trigger Page to capture the needed data Trigger Page means your data is divided into many pages The size of each...

Page 67: ...64 512K This capability doesn t exist 1 1 1 32 1M 1 1 1 16 2M 1 1 1 8 4M 1 1 1 1 Applicable Models LAP C 32128 LAP C 321000 LAP C 322000 RAM Page Min Max Min Max Min Max 2K 1 8192 1 8192 1 8192 16K 1...

Page 68: ...e would pop up below purchase dialog box In this dialog box click Purchase to login the ZPP Store to purchase this function Trigger Count Set the trigger count The value can be set between 1 65535 or...

Page 69: ...and Clear Highlight Tips to choose Even the Find dialog box is closed the Highlight Tips still exists which only can be cleared by clicking Clear Highlight Tips option Result When Found Mark the data...

Page 70: ...ditions on current page as is the control panel Note 4 If page switched then find would be done based on conditions on the page after switching with starting at the current position Note 5 Switching b...

Page 71: ...2nd channel the other signal will not be captured Select Filter Type There are Filter Condition and Inverse Filter Condition to choose the default is Filter Condition Reserved Area There are During t...

Page 72: ...1 04 04 72 FM07I4A Step 1 Select the Protocol Decoders and expand the categories then select one Protocol Decoders Also users can input the name of Protocol Decoders in the Find box to find it quickly...

Page 73: ...Smart User s Manual V1 04 04 73 FM07I4A Step 2 Set parameters needed of the Protocol in the Setting dialog box Then press Next...

Page 74: ...Smart User s Manual V1 04 04 74 FM07I4A Step 3 Finally click the Finish and the I2C Protocol can be used To build a Bus first select the Bus type...

Page 75: ...Smart User s Manual V1 04 04 75 FM07I4A Step 1 Click Next to enter into the following interface...

Page 76: ...elect a channel in the left box firstly then click to move it to the right box click OK to confirm then the selected channel is added Select the channel in the right box and click to delete it Ctrl an...

Page 77: ...Smart User s Manual V1 04 04 77 FM07I4A Step 3 Click Advanced Settings to set Chip Select or Latch Settings For some models Latch function needs to be paid to use see below image...

Page 78: ...to purchase this function Step 4 The channels included in the Bus can t do CS setting After CS is activated select one channel in the left box and click to move it to the right box then it can be set...

Page 79: ...Smart User s Manual V1 04 04 79 FM07I4A Step 5 In the end click Finish then the Bus is build...

Page 80: ...Manual V1 04 04 80 FM07I4A Step 6 See above image Bus 0 includes A0 A1 A3 in low level is the CS channel the Latch is set as sampling at Rising Edge in A0 channel To add a channel firstly select the...

Page 81: ...Smart User s Manual V1 04 04 81 FM07I4A Step 1 Click the Next to enter into the following interface...

Page 82: ...users should select one channel in the left box firstly then click to move it to the right box click OK to confirm then the selected channel is added Select the channel in the right box and click to...

Page 83: ...Smart User s Manual V1 04 04 83 FM07I4A Step 3 Channel A0 A1 and A2 are added Click Next to enter into the following interface...

Page 84: ...meters of all Logic Analyzers are set to the same One signal will be sent to the synchronization channels at that time all Logic Analyzers start capturing data together The software will process the c...

Page 85: ...e LA connecting with the software and Slave is the LA for stacking Users shall select at least 2 at most 4 LAs to stack click Previous or Next to adjust their order Synchronous Channel It is A0 by def...

Page 86: ...dows USB Driver from the GwInstek Website www gwinstek com If Agilent oscilloscope is used for stacking please download the Windows USB Driver from the Agilent Website www chem agilent com If BK Preci...

Page 87: ...rs externally After triggers the oscilloscope will notify the LA to capture data b Oscilloscope is the Master LA is the Slave The Trigger Out of oscilloscope connects with any channel of LA user defin...

Page 88: ...n the waveform view area of LA Users also can click the Color button to change the channel s color If the Show display inputs only is selected only the activated DSO channels can be displayed in the w...

Page 89: ...l scale which is 1 1ns 1 50s Stacking Delay It is used to align the T bar and the T bar of LA when the main program is used to display the oscilloscope s waveform The range is 1000000ps 1000000ps Trig...

Page 90: ...rm 4 13 Noise Filter Setup After Noise Filter is activated users can select one channel in the left box and click to add it into the right box then this channel can do noise filtering Select the chann...

Page 91: ...r own Files Comparison port Users can capsule the Files Comparison user interface UI into GUI DLL and design a port to be used in the communication between GUI DLL and the main program GUI uses non mo...

Page 92: ...ference during data contrasting None 10 clocks can be set the default is None Show files horizontally Display the two files horizontally the default is not selected Synchronize navigation The two hori...

Page 93: ...rast PASS means the data in the channel is the same in two files FAIL means the data is different of differences Display the quantity of differences Close Close Files Comparison dialog box 2 Files Com...

Page 94: ...can drag the slider or roll the mouse wheel to see the differences which are marked by orange wavy line 4 15 Math Operation 4 15 1 Boolean Operation Boolean Operation There are AND OR NAND NOR XOR XN...

Page 95: ...ion Users can select two channels or buses to do mathematical operation of add subtract multiply and divide Bus option is available if two or more buses exist Output Name Input the name of operation r...

Page 96: ...emory Page The memory size of each page is 512K If the data in one single page is larger than 512K inputting page number in the Go To dialog box and clicking Goto will go to its relevant position For...

Page 97: ...Smart User s Manual V1 04 04 97 FM07I4A Bar Go to the specified Bar such as A Bar B Bar Z Bar The default is A Bar If B Bar is selected it will be displayed in the middle of the screen see below image...

Page 98: ...Smart User s Manual V1 04 04 98 FM07I4A...

Page 99: ...nd Not In Range to choose Min Input the Min value Max Input the Max value Color Select color for the specified data that fitting the Bus condition Below is an example Open the Specific Bus Data Displa...

Page 100: ...ge It is at the top layer after opened the main program cannot perform any other operation This function can t be performed if the data is being processed See below image Real time Frequencies Display...

Page 101: ...Smart User s Manual V1 04 04 101 FM07I4A...

Page 102: ...the waveform in the waveform view area The size of the selection frame is in inverse proportion to the zoom rate the larger the zoom rate is the smaller the size of the selection frame is Users can a...

Page 103: ...one or more Buses Protocol Analyzers according to their packet order and display the content of each packet according to its order in the Bus memory It only can display the packet of Bus Protocol Anal...

Page 104: ...hoose It is ms by default Separate lines automatically If the data of one packet is too long to be displayed in one line then it would be displayed in two or more lines automatically It is selected by...

Page 105: ...Smart User s Manual V1 04 04 105 FM07I4A Packet Find Find particular packet...

Page 106: ...et with a bar Right click one packet in the packet list and select this item to mark it with a bar the beginning of the packet would be in the middle of waveform display area Hide Hide the current sel...

Page 107: ...ch channel including Full Period Positive Period Negative Period Conditional Position Conditional Positive Period Conditional Negative Period and so on The statistic range can also be changed Channel...

Page 108: ...parameters to be displayed Except Probe all parameters are selected by default Filter Set conditions to filter the unneeded periods only the periods that fitting the conditions can be counted This fun...

Page 109: ...tion will be marked in red Statistics Range Right click in the Statistics area and select Statistics Area can pop out this dialog box users can set the data range that need to be counted Refresh If th...

Page 110: ...The up part and the Address part are locked In below image the part above the thick line is the up part which with the Address part are always visible when dragging the sliding bar Memory View is mai...

Page 111: ...tion of the packet which the reaction bar locates will be displayed in the Memory Analyzer window Columns Per Line Set the quantity of cells displayed in the Memory View 16 by default they also can se...

Page 112: ...hite background in the cells At the same address if the read data is different with the write data then the cell will show error in yellow background and show the last read data of that address If suc...

Page 113: ...1 04 04 113 FM07I4A 4 23 Trace Format Users can change the width and color of waveform line Bus Protocol Analyzer outline and analog waveform line Take A0 as an example set its width to 3 and color to...

Page 114: ...l Decoder is free or not Users can login our website http www zeroplus com tw to get latest information about Protocol Decoders or connect our customer service representatives Please refer to the Prot...

Page 115: ...IBPI Differential Manchester MCU 51 DECODE Serial Wire Debug SWD DIGITAL LOGIC MDDI SHT11 DigRF MHL CBUS SIGNIA 6210 DM114 DM115 MICROWIRE SLE4442 DMX512 MICROWIRE EEPROM 93C SMBus 2 0 DP AUX Channel...

Page 116: ...Smart User s Manual V1 04 04 116 FM07I4A USB PD3 0 HID Over I2C CCIR601...

Page 117: ...Smart User s Manual V1 04 04 117 FM07I4A 5 FAQ 5 1 Hardware 5 2 Software 5 3 Registration 5 4 Technical Information 5 5 Others...

Page 118: ...d during compression Which one A No D port has been set to be disabled during compression LAP D Series models don t support compression H06 Why the negative voltage can do level setting A This allows...

Page 119: ...oom in out the waveform SW08 How many seconds the delay can last in the Filter Delay function A Different sampling frequency has different value the software provides a suggested value SW09 How to get...

Page 120: ...s Manual V1 04 04 120 FM07I4A A In order to acquire the best waveform from the Logic Analyzer and make the full use of memory in the Double Mode filter function can be used but the signal delay is not...

Page 121: ...representatives will respond ASAP after receiving it RG04 How may I register if the purchasing date was more than one month ago A Send fax the warranty card to Zeroplus and email call our customer se...

Page 122: ...to the logic waveform TI04 What is the synchronous State Mode A Since the sampling clock and the object under test may have direct relation and be controlled by it so the sampling clock and the signa...

Page 123: ...nal outside the Logic Analyzer It is used for the simultaneous testing of 2 test tools For example one Logic Analyzer can be started by one signal from another test tool Or when it is triggered it can...

Page 124: ...ence caused by the lack of information pertaining to Logic Analyzers We are working very hard on producing multilingual information and documentations about the Logic Analyzer Visit our website for th...

Page 125: ...channel is connected with the object under test properly 2 Please make sure the ground line of channel is connected with the ground end of the object under test properly 3 Please make sure the settin...

Page 126: ...Smart User s Manual V1 04 04 126 FM07I4A 7 Appendix 7 1 Hot Keys 7 2 Contact Us...

Page 127: ...and Hand mode Z Zoom out the waveform Shift Z Zoom in the waveform Ctrl Alt P Whole page mode Ctrl Z Return to the previous zoom selection Ctrl Y Go to the next zoom selection F1 Open the Help file A...

Page 128: ...ete the selected item F2 Rename the selected item Ctrl A Select all channels in the channel area Number Key Move the corresponding Bar and the waveform to the middle of screen Shift Number Key Move th...

Page 129: ...ist Hsinchu City 30052 Taiwan R O C Tel 886 3 542 6637 Ex 87 Fax 886 3 542 4917 ZIP Code 30052 E Mail hunter zeroplus com tw Taiwan Chung Ho City ZEROPLUS TECHNOLOGY CO LTD Address 2F NO 123 Jian Ba R...

Page 130: ...9 Pudong New Area Shanghai City Tel 86 21 50155235 6 Fax 86 21 50155235 607 ZIP Code 201318 E Mail endless_cn zeroplus com tw kan zeroplus com tw Users can download the newest Software and User Manual...

Reviews: