Z 1500/2000-135/155/175
38
Cable routing
www.zepro.com
Figure 67.
Battery capacity and definition of the length of the earth and main power cables
-
+
-
+
L
L
U
min
I
min
I
min
U
min
5.2
Sizing electrical systems
Ensure that the battery and charger capacity is sufficient for the product in question and that cable with suf
-
ficient cross-sectional area is used.
Hydraulic unit 7050
12 volt
24 Volt
Pump - Motor unit
245 A
145 A
Minimum recommended conductor cross-sectional area
(copper cables, plus and minus cables)
Control power cable
1.5 mm
2
1.5 mm
2
Main power cable, L < 8m
35 mm
2
35 mm
2
Main power cable, L = 8 - 15m
50 mm
2
35 mm
2
Main power cable, L > 15m
-
50 mm
2
Battery
Min. capacity, I
min
(available for lift)
180 Ah
180 Ah
Min. voltage during operation, U
min
(at lift)
9 Volt
18 Volt
NOTE!
Make sure the tail lift has access to the minimum recommended current capacity (I
min
)
.
Some vehicle models have restrictions regarding the amount of current the lift can access from the existing
battery. Some vehicle models do not fully charge the battery. It may therefore be necessary to switch to a bat
-
tery and sometimes also to a charger with a larger capacity.