Z 1500/2000-135/155/175
Installation
33
www.zepro.com
4.9.3 Tail lift with angle sensor IFM for autotilt
1. Install the angle sensor on the platform using the nuts, bolts and washers supplied and attach the cable
using cable ties; see Figure 57
2. Route the cables and secure with cable ties
.
Connection is described later in section 6.
Figure 57. Installing an angle sensor for auto tilt
Bracket on the platform
Autotilt angle setting
By default, the autotilt angle is set to 0°. If necessary, the posi
-
tion of the angle sensor (autotilt angle) can be adjusted.
1. Loosen the two screws without removing them, see Figure 58.
2. Adjust the position of the angle sensor to the desired angle,
see Figure 58.
3. Retighten the screws.
Figure 58.
Adjusting the autotilt angle