Z 1500/2000-135/155/175
Installation
29
www.zepro.com
4.6
Adjustable underrun protection
Test the position of the underrun protection without
tightening the bolts to check that the statutory
dimensions are obtained. Adjust if necessary then
tighten the bolts with a torque wrench.
1. Fit the inner part of each bracket at one of four
heights. Select the height that meets the statu
-
tory requirements, see section
"3.2 Statutory
dimensions" on page 9. Use the corresponding
bolts M12x100. Assemble without tightening the
bolts, see Figure 50.
2.
Fit the outer part of each bracket at one of five
positions. Select a position that meets the statu
-
tory requirements, see section
"3.2 Statutory
dimensions" on page 9.
Use the associated bolts M12x80. Assemble
without tightening the bolts. See
Figure 50.
3. Check that the installation meets the statutory re-
quirements, see section
"3.2 Statutory dimensions"
on page 9.
4. Tighten all the bolts using a torque wrench.
Tight-
ening torque: 80 Nm.
Figure 48.
The inner part of the brack
-
ets can be fitted at one of four heights
Figure 49.
The outer part of the brackets
can be fitted in one of five positions
Figure 50. Installing underrun protection
610
610
760
760
810
810
710
710
660
660
2x M12x100 8.8
80Nm
3x M12x80 8.8
80Nm
304
304
244
244
196
196
136
136
m
WARNING!
Check carefully that there is no risk of the
outer part of each bracket colliding with any
part of the cylinders when using the lift’s
functions. In particular, check in relation to the
cylinders’ hose connections, especially when
the outer part of the brackets are installed a
long way in..