Z 1500/2000-135/155/175
Cable routing
41
www.zepro.com
5.4
Control power cable
When using cab switches (CS), route the control current cable from the cab switch CS to
the tail lift cable
grommet. Connection is described later in section 6.
5.5
Open platform alarm
ZEPRO recommends the installation of an alarm for open platform. This can be in the form of warning light in
the cab or when mounted on a trailer, a lamp mounted on the outside of the body, visible in the rear view mir-
ror from the driver's cab. Route the lamp cables to the tail lift cable grommet. Connection is described later in
section 6.
5.6
Foot controller / Warning lights
If the tail lift is equipped with warning lights and/or foot controller, their cabling must be routed and connect-
ed according to the following description.
1. Connect the supplied cable to the connector on the foot controller/warning lighting cable.
2. Route the cable and install with cable ties according to Figure 71 and Figure 72. The quick connector
must be positioned in such a way that it does not conflict with the underrun protection while the lift arm
is in motion. Measure the distance (A) from the centre of the lift arm shaft to the centre of the underrun
protection; see Figure 73.
3. Measure the same distance (A) on the lift arm; see Figure 73.
4. Then place the quick connector at least 100 mm outside or inside the measured point (A); see Figure 73.
Connection is described later in section 6.
IMPORTANT!
Route the cable between the platform and the lift arm tube such that it is well protected when the platform touches the ground.
Position the quick connector in such a way that it does not conflict with the underrun protection while the lift arm is in motion.
Leave enough slack to the first cable tie to avoid the risk of damage to the cable during lift operation.
Figure 71.
Installing cabling
Figure 72.
Installing cabling
Figure 73.
Quick con
-
nector location
A
A
100 mm
200 mm