CMM
61211-1310402
CONTURA
4-5
Size
12/18/10
12/24/10
Sound pressure level of the
CMM
[dBA]
<70
Coordinate measuring machine parameters
Category
Parameter
Overvoltage category
II
Degree of contamination
2
Protection class
I
Electrical data
Line voltage
100 - 240 V~ (±10 %)
Type of current
1/N/PE
Frequency
50 - 60 Hz (±3.5 %)
Power consumption
Maximum
1000 VA
Typical
200 W (depending on the option)
Fuse (provided by the customer)
230 - 240 V
C 16 A
100-125 V
15 A
Amount of heat generated:
CMM
2200 kJ
Data station and peripheral devices
3800 kJ
Compressed air
Certain requirements have to be met before connecting the compressed
air in order not to impair the function of the CMM.
Requirements
Pressure
6-8 bar
Summary of Contents for CONTURA
Page 55: ...4 61211 1310402 CONTURA 4 1 Technical data This chapter contains CMM 4 2 Technical data...
Page 62: ...CMM 4 8 61211 1310402 CONTURA...
Page 68: ...Installation 5 6 61211 1310402 CONTURA...
Page 90: ...Setting up the workpiece 6 22 61211 1310402 CONTURA 200 100 100 200 100 600 Size 9 12 Z...
Page 91: ...Setting up the workpiece 61211 1310402 CONTURA 6 23 600 100 600 100 600 100 Size 9 18 Z...
Page 92: ...Setting up the workpiece 6 24 61211 1310402 CONTURA 600 100 600 100 800 100 Size 12 18 Z...
Page 122: ...Terminating the measuring operation 7 26 61211 1310402 CONTURA...
Page 130: ...Service features 8 8 61211 1310402 CONTURA...
Page 150: ...2Glossary 2 61211 1310402 CONTURA...
Page 156: ...6Alphabetic index 6 61211 1310402 CONTURA...
Page 157: ......
Page 158: ...CONTURA Operating instructions 2022 04 29 61211 1310402...