background image

 

 

____________________  

12

  ____________________   

There   are   15   beeps   representing   the   height   from   the   ground   at   which   the   door   will   stop   and   not   reverse   

when   it   encounters   an   obstruction.      The   beeps   relate   to   roughly   1/8”   steps   with   4”   cable   drums   -­‐   press   and   
release   the   ILLUMINATED   button   after   the   required   number   of   beeps.      The   default   is   4   beeps,   you   MUST   test   
that   the   door   will   still   reverse   off   a   1.5”   high   object   (or   a   2”   by   4”   board   laid   flat)   after   altering   this   setting.   
Release   after   the   

third

   beep   to   

enable   or   reset   the   service   due   reminder

,   there   are   two   confirmation   beeps.      

The   Control   Box   will   beep   

during

   closing   after   9,900   cycles   have   been   completed   and   beep   for   10   seconds   

before

   closing   after   10,000   door   cycles   have   been   completed.      The   reminder   is   disabled   by   default.   

Release   after   the   

fourth

   beep   to   

disable   the   service   due   reminder

,   there   are   four   confirmation   beeps.      The   

service   due   reminder   will   not   come   back   on   until   it   has   been   enabled   again   –   this   is   the   factory   default.   
Release   the   ILLUMINATED   button   after   the   

fifth

   beep   for   

safety   edges

.      This   option   switches   between   safety   

types:      One   long   beep   indicates   that   the   safety   input   works   to   the   ground   for   use   with   photo   eyes   (default);   
two   beeps   indicate   that   the   safety   input   is   disabled   just   before   the   ground   for   use   with   safety   edges.   

User   functions   using   the   illuminated   button

   

With   the   door   fully   closed   or   after   the   power   has   been   turned   on,   press   and   

HOLD

   the   

ILLUMINATED

   button,   there   is   one   medium   beep   every   3   seconds:   

Release   the   ILLUMINATED   button   after   the   

first

   beep   for   

vacation   mode

.      

The   light   goes   out   and   the   radios   and   external   inputs   are   all   ignored   until   the   
button   has   been   pressed   again   to   leave   vacation   mode.   
Release   the   ILLUMINATED   button   after   the   

second

   beep   to   obtain   the   

cycle   

count

:   there   are   long   beeps   for   100,000's,   medium   beeps   for   10,000’s,   short   

beeps   for   1,000's   and   rapid   beeps   for   100's   of   open-­‐close   cycles   completed.   
Release   the   ILLUMINATED   button   after   the   

third

   beep   to   obtain   the   

system   status

:   there   are   long   and   short   

beeps   in   groups   of   8   beeps,   the   length   of   the   beeps   indicate   the   status   of   different   parts   of   the   system.      
Refer   to   the   advanced   instructions   for   further   information.   
Release   the   ILLUMINATED   button   after   the   

fourth

   beep   for   the   

serial   number

:   there   is   a   unique   sequence   of   

long   and   short   beeps   in   groups   of   8   beeps.   

Factory   reset   using   the   PROGRAM   Button   

Unplug   the   power   cable   or   switch   off   the   power,   press   and   

HOLD

   the   

PROGRAM

   button   and   plug   the   power   cable   back   in   or   switch   on   the   

power   –   there   is   one   beep   every   4   seconds:   
Release   the   PROGRAM   button   after   the   

second

   beep   for   the   

factory   

reset

:      There   is   a   sequence   of   beeps   and   flashes   lasting   for   several   

seconds   as   all   of   the   factory   default   settings   are   restored.   

The   factory   default   settings   are:   Obstruction   tolerance   6,   open   to   a   physical   obstruction,   closing   speed   

change   height   12”,   closing   soft   start   duration   4   seconds,   auto-­‐close   time   15   seconds

*

,   reversing   decision   

height   ¾”,   service   due   reminder   disabled   and   safety   input   active   to   the   ground.   

For   further   information,   please   refer   to   the   8825-­‐R4   advanced   installer   guide   at   

www.tuckerzap.com

   

   

*   NOTE:   The   auto-­‐close   function   is   only   active   if   the   auto-­‐close   switch   is   set   to   ON.   

Summary of Contents for 8825-R4

Page 1: ......

Page 2: ...fore installing the opener 4 Where possible install the door opener 7 feet or more above the floor Mount the emergency release 6 feet above the floor 5 Do not connect the opener to the source of power...

Page 3: ...e cela est possible installer l l ouvre porte 2 14m ou plus au dessus du sol Monter le d verrouillage d urgence 1 83m au dessus du sol 5 Ne pas brancher l ouvre porte la source d alimentation lectriqu...

Page 4: ...15 3 Install the Control Head Page 5 15 4 Fit the Manual Override Page 6 16 5 Fit the Control Box Page 6 16 6 Fit the optional Automatic Lock Page 7 17 7 Connect to the power supply Page 7 17 8 Insta...

Page 5: ...ing the operator 5 Fitting the Control Head 6 Fitting the Manual Override Lever 7 Fitting the Control Box 7 8 Fitting the optional Automatic Lock 8 Supply outlet information 8 Accessory wiring 8 Built...

Page 6: ...pending on the door position A significant advantage of the ZAP drive system with its soft start and its fast obstruction sensing is that when an object obstructs the door s travel the cables will pro...

Page 7: ...e the other end to the torque arm fixing hole on the Control Head use the supplied spacer if the offset is not enough to clear the drum Pic 5 Pic 5 Align the Control Head driven pulley s keyway with t...

Page 8: ...ecure the lever using the M5 screws and flange nuts supplied Pic 9 Pic 9 Place the hook in the cable D shackle or a convenient link of the chain and ensure that the lever is slightly above horizontal...

Page 9: ...d Pic 15 Pic 15 SUPPLY OUTLET A 115V 60Hz grounding type outlet is required for the 8825 R4 this should be installed by a qualified electrician in accordance with the local electrical codes within 4 o...

Page 10: ...AFETY and Pic 19 Note The supplied photo eyes are not polarity sensitive and can be wired either way around Pic 19 When the photo eyes are properly aligned the red safety light on the Control Box circ...

Page 11: ...rd stage to end 4 Once the third stage of the calibration process is complete the door will be closed and the Operator Light will be lit with the beeper sounding once every 5 seconds to indicate entry...

Page 12: ...obstruction A calibration reset pages 9 10 is required for a new setting to take effect Release the PROGRAM button after the fourth beep to program the closing speed change point 14 beeps representing...

Page 13: ...ILLUMINATED button after the first beep for vacation mode The light goes out and the radios and external inputs are all ignored until the button has been pressed again to leave vacation mode Release t...

Page 14: ...omatically opens REASON REMEDY A The V belt tension is too loose and the belt is slipping over the motor pulley Increase the tension by releasing the Manual Override Lever and screwing the hook in a f...

Page 15: ...e ZAP Controller has not been calibrated to this door Refer to the calibration process on pages 9 and 10 C The obstruction tolerance may be too low Refer to the Installer Programming instructions on p...

Reviews: