background image

 

 

____________________  

8

  ____________________   

Feed   the   Control   Cable   in   through   the   hole   in   

the   back   of   the   Control   Box.      Plug   the   Control   
Cable   into   the   lid   mounted   circuit   board   (Pic   13)   
and   fix   the   cable   at   suitable   points   between   the   

Control   Box   and   the   Control   Head.      Coil   any   
excess   cable   and   secure   it   near   to   the   Control   
Head.   

   
   
   

   
   
   
   

Pic   13   

   

FITTING   THE   AUTOMATIC   LOCK   

If   the   optional   Automatic   Lock   is   required,   
mount   it   on   the   door   track   in   such   a   position   
that   the   cable   reaches   the   Control   Box   and   the   

plunger   is   1/2”   above   a   track   roller   when   the   
door   is   fully   closed.   
Use   the   Automatic   Lock   template   on   the   back   of   

the   instructions   to   drill   two   1/4”   mounting   holes   
and   one   9/16”   hole   for   the   plunger.      Mount   the   
lock   to   the   track   using   the   supplied   M5   screws   
and   flange   nuts   making   sure   that   the   lock   

override   tab   is   towards   the   bottom   (Pic   14).   

 

Pic   14   

   

Fix   the   cable   at   suitable   points   between   the   lock   
and   the   Control   Box,   feed   the   end   into   the   back   
of   the   Control   Box   enclosure   and   plug   it   into   the   

lid   mounted   circuit   board   (Pic   15).   

 

Pic   15   

SUPPLY   OUTLET   

A   115V   60Hz   grounding   type   outlet   is   required   
for   the   8825-­‐R4,   this   should   be   installed   by   a   
qualified   electrician   in   accordance   with   the   local   
electrical   codes,   within   4’   of   the   Control   Head.   

To   reduce   the   risk   of   electric   shock,   this   
equipment   has   a   grounding   type   plug,   that   has   a   
third   (grounding)   pin.      This   plug   will   only   fit   into   

a   grounding   type   outlet.      If   the   plug   does   not   fit   
into   the   outlet,   contact   a   qualified   electrician   to   
install   the   proper   outlet.      Do   not   change   the   plug   

in   any   way.      Plug   the   three   pin   supply   plug   into   
the   outlet   and   apply   mains   power   to   the   system.   
   

A   small   green   indicator   light   should   be   visible   in   
the   outer   metal   plate   of   the   Control   Head   (Pic   
16)   and   the   button   in   the   lid   of   the   Control   Box   
should   be   illuminated.   

 

Pic   16

   

   

ACCESSORY   WIRING   

A   24Vdc   500mA   supply   is   provided   on   the   5   way   
field   wiring   terminal   block;   this   supply   is   turned   
off   when   the   system   is   put   into   vacation   mode.      

There   is   an   input   provided   for   a   dry   normally   
open   contact   (Pic   17).      This   can   be   used   to   wire   
up   a   third   party   radio   receiver   or   a   remote   

button.      This   input   will   cycle   the   door   in   the   
same   way   as   the   illuminated   button   but   without   
the   programming   features.   

   

                                                            Pic   17      

   

   

+24V   dc   

Relay   

Common   

Summary of Contents for 8825-R4

Page 1: ......

Page 2: ...fore installing the opener 4 Where possible install the door opener 7 feet or more above the floor Mount the emergency release 6 feet above the floor 5 Do not connect the opener to the source of power...

Page 3: ...e cela est possible installer l l ouvre porte 2 14m ou plus au dessus du sol Monter le d verrouillage d urgence 1 83m au dessus du sol 5 Ne pas brancher l ouvre porte la source d alimentation lectriqu...

Page 4: ...15 3 Install the Control Head Page 5 15 4 Fit the Manual Override Page 6 16 5 Fit the Control Box Page 6 16 6 Fit the optional Automatic Lock Page 7 17 7 Connect to the power supply Page 7 17 8 Insta...

Page 5: ...ing the operator 5 Fitting the Control Head 6 Fitting the Manual Override Lever 7 Fitting the Control Box 7 8 Fitting the optional Automatic Lock 8 Supply outlet information 8 Accessory wiring 8 Built...

Page 6: ...pending on the door position A significant advantage of the ZAP drive system with its soft start and its fast obstruction sensing is that when an object obstructs the door s travel the cables will pro...

Page 7: ...e the other end to the torque arm fixing hole on the Control Head use the supplied spacer if the offset is not enough to clear the drum Pic 5 Pic 5 Align the Control Head driven pulley s keyway with t...

Page 8: ...ecure the lever using the M5 screws and flange nuts supplied Pic 9 Pic 9 Place the hook in the cable D shackle or a convenient link of the chain and ensure that the lever is slightly above horizontal...

Page 9: ...d Pic 15 Pic 15 SUPPLY OUTLET A 115V 60Hz grounding type outlet is required for the 8825 R4 this should be installed by a qualified electrician in accordance with the local electrical codes within 4 o...

Page 10: ...AFETY and Pic 19 Note The supplied photo eyes are not polarity sensitive and can be wired either way around Pic 19 When the photo eyes are properly aligned the red safety light on the Control Box circ...

Page 11: ...rd stage to end 4 Once the third stage of the calibration process is complete the door will be closed and the Operator Light will be lit with the beeper sounding once every 5 seconds to indicate entry...

Page 12: ...obstruction A calibration reset pages 9 10 is required for a new setting to take effect Release the PROGRAM button after the fourth beep to program the closing speed change point 14 beeps representing...

Page 13: ...ILLUMINATED button after the first beep for vacation mode The light goes out and the radios and external inputs are all ignored until the button has been pressed again to leave vacation mode Release t...

Page 14: ...omatically opens REASON REMEDY A The V belt tension is too loose and the belt is slipping over the motor pulley Increase the tension by releasing the Manual Override Lever and screwing the hook in a f...

Page 15: ...e ZAP Controller has not been calibrated to this door Refer to the calibration process on pages 9 and 10 C The obstruction tolerance may be too low Refer to the Installer Programming instructions on p...