background image

 

 

____________________  

1

  ____________________   

IMPORTANT INSTALLATION 

INSTRUCTIONS

 

WARNING: 

To reduce the risk 

of severe injury or death:

 

1. 

READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 

 

2. 

Install only on a properly balanced garage door.  An improperly 

balanced door has the potential to inflict severe injury.  Have a 

qualified service person make repairs to cables, spring assemblies 

and other hardware before installing the opener. 

 

3. 

Remove all ropes and remove or make inoperative all locks 

connected to the garage door before installing the opener. 

 

4. 

Where possible install the door opener 7 feet or more above the floor.  

Mount the emergency release 6 feet above the floor. 

 

5. 

Do not connect the opener to the source of power until instructed to 

do so. 

 

6. 

Locate the control button: 

a.  Within sight of the door. 

b.  At a minimum height of 5 feet so small children are not able to 

reach it. 

c.  Away from all moving parts of the door. 

 

7. 

Install the Entrapment Warning Label next to the control button in a 

prominent location.  Install the Emergency Release Marking.  Attach 

the marking on or next to the emergency release. 

 

8. 

After installing the opener, the door must reverse when it contacts a 

1.5 inch high object (or a 2” by 4” board laid flat) on the floor. 

Summary of Contents for 8825-R4

Page 1: ......

Page 2: ...fore installing the opener 4 Where possible install the door opener 7 feet or more above the floor Mount the emergency release 6 feet above the floor 5 Do not connect the opener to the source of power...

Page 3: ...e cela est possible installer l l ouvre porte 2 14m ou plus au dessus du sol Monter le d verrouillage d urgence 1 83m au dessus du sol 5 Ne pas brancher l ouvre porte la source d alimentation lectriqu...

Page 4: ...15 3 Install the Control Head Page 5 15 4 Fit the Manual Override Page 6 16 5 Fit the Control Box Page 6 16 6 Fit the optional Automatic Lock Page 7 17 7 Connect to the power supply Page 7 17 8 Insta...

Page 5: ...ing the operator 5 Fitting the Control Head 6 Fitting the Manual Override Lever 7 Fitting the Control Box 7 8 Fitting the optional Automatic Lock 8 Supply outlet information 8 Accessory wiring 8 Built...

Page 6: ...pending on the door position A significant advantage of the ZAP drive system with its soft start and its fast obstruction sensing is that when an object obstructs the door s travel the cables will pro...

Page 7: ...e the other end to the torque arm fixing hole on the Control Head use the supplied spacer if the offset is not enough to clear the drum Pic 5 Pic 5 Align the Control Head driven pulley s keyway with t...

Page 8: ...ecure the lever using the M5 screws and flange nuts supplied Pic 9 Pic 9 Place the hook in the cable D shackle or a convenient link of the chain and ensure that the lever is slightly above horizontal...

Page 9: ...d Pic 15 Pic 15 SUPPLY OUTLET A 115V 60Hz grounding type outlet is required for the 8825 R4 this should be installed by a qualified electrician in accordance with the local electrical codes within 4 o...

Page 10: ...AFETY and Pic 19 Note The supplied photo eyes are not polarity sensitive and can be wired either way around Pic 19 When the photo eyes are properly aligned the red safety light on the Control Box circ...

Page 11: ...rd stage to end 4 Once the third stage of the calibration process is complete the door will be closed and the Operator Light will be lit with the beeper sounding once every 5 seconds to indicate entry...

Page 12: ...obstruction A calibration reset pages 9 10 is required for a new setting to take effect Release the PROGRAM button after the fourth beep to program the closing speed change point 14 beeps representing...

Page 13: ...ILLUMINATED button after the first beep for vacation mode The light goes out and the radios and external inputs are all ignored until the button has been pressed again to leave vacation mode Release t...

Page 14: ...omatically opens REASON REMEDY A The V belt tension is too loose and the belt is slipping over the motor pulley Increase the tension by releasing the Manual Override Lever and screwing the hook in a f...

Page 15: ...e ZAP Controller has not been calibrated to this door Refer to the calibration process on pages 9 and 10 C The obstruction tolerance may be too low Refer to the Installer Programming instructions on p...

Reviews: