QUICK   PROGRAMMING   GUIDE   

Radio   programming   using   the   LEARN   button   (see   page   9)

 

   

Locate   the   small   

LEARN

   button   on   the   top   edge   of   the   radio   receiver   module   inside   

the   Control   Box.      Press   the   

LEARN

   button:   

To   

program

   a   transmitter,   release   the   learn   button   when   the   receiver   light   comes   on:   

Press   and   hold   the   required   button   on   the   

transmitter

   until   the   receiver   light   starts   to   

flash.   
To   

erase

   all   stored   transmitters,   release   the   learn   button   when   the   receiver   light      

turns   off   again   (after   about   12   seconds).   

Installer   programming   using   the   PROGRAM   Button   

Press   and   

HOLD

   the   

PROGRAM

   button,   there   is   one   beep   every   3   seconds:   

Release   the   PROGRAM   button   after   the   

first

   beep   for   the   

calibration   reset

   –   

see   pages   9   &   10   for   further   details.   
Release   the   PROGRAM   button   after   the   

second

   beep   to   alter   the   

obstruction   

tolerance

:   

There   are   15   beeps   representing   increasing   tolerance   to   obstructions   –   press   and   release   the   ILLUMINATED   
button   after   the   required   number   of   beeps.      The   default   setting   is   6   and   a   calibration   reset   (pages   9   &   10)   is   
required   for   any   new   setting   to   take   effect.   
Release   the   PROGRAM   button   after   the   

third

   beep   to   alter   the   

open   stopping   mode

:   

This   alternates   between   programming   the   control   head   to   open   to   a   physical   obstruction   such   as   pusher   

springs   or   the   cable   drums   (2   beeps   and   2   flashes)   or   open   to   the   height   determined   during   the   initial   slow   
calibration   runs   (1   long   beep   and   2   flashes).      The   default   setting   is   to   open   to   a   physical   obstruction.      A   
calibration   reset   (pages   9   &   10)   is   required   for   a   new   setting   to   take   effect.   
Release   the   PROGRAM   button   after   the   

fourth

   beep   to   program   the   

closing   speed   change   point

:   

14   beeps   representing   2”   height   increases   with   4”   cable   drums   –   press   and   release   the   ILLUMINATED   button   

after   the   required   number   of   beeps   e.g.   the   default   of   6   beeps   will   cause   the   door   to   slow   down   when   it   is   
12”   from   the   ground.      A   calibration   reset   may   be   required   after   altering   the   closing   speed   change   height.   
Release   the   PROGRAM   button   after   the   

fifth

   beep   to   alter   the   

soft   start   time

:   

Press   and   release   the   ILLUMINATED   button   after   the   required   closing   soft   start   time   (0.5   to   10   seconds,   
default   4).      The   door   will   ramp   up   to   full   closing   speed   within   the   programmed   time.      The   opening   soft   start   

time   is   set   to   half   the   closing   soft   start   time.      A   calibration   reset   may   be   needed   after   changing   the   soft   start.   

Service   programming   using   the   illuminated   button

   

Unplug   the   power   cable   or   switch   off   the   power,   press   and   

HOLD

   the   

ILLUMINATED

   button   and   plug   the   power   cable   back   in   or   switch   on   the   power   -­‐   

there   is   a   beep   every   4   seconds:   
Release   the   ILLUMINATED   button   after   the   

first

   beep   to   alter   the   

auto-­‐close   timer

:   

Press   and   release   the   ILLUMINATED   button   to   start   timing   and   press   and   release   
the   ILLUMINATED   button   again   after   the   required   time   (5s   to   96s,   default   15s).      
The   auto-­‐close   DIP   switch   on   the   control   board   must   be   switched   ON   for   the   auto-­‐

close   function   to   be   active.      The   beeper   will   sound   and   the   operator   light   will   flash   
during   the   final   5   seconds   prior   to   the   start   of   an   automatic   close.   
Release   the   ILLUMINATED   button   after   the   

second

   beep   to   store   the   

reversing   decision   height

:   

LEARN   

button   

Summary of Contents for 8825-R4

Page 1: ......

Page 2: ...fore installing the opener 4 Where possible install the door opener 7 feet or more above the floor Mount the emergency release 6 feet above the floor 5 Do not connect the opener to the source of power...

Page 3: ...e cela est possible installer l l ouvre porte 2 14m ou plus au dessus du sol Monter le d verrouillage d urgence 1 83m au dessus du sol 5 Ne pas brancher l ouvre porte la source d alimentation lectriqu...

Page 4: ...15 3 Install the Control Head Page 5 15 4 Fit the Manual Override Page 6 16 5 Fit the Control Box Page 6 16 6 Fit the optional Automatic Lock Page 7 17 7 Connect to the power supply Page 7 17 8 Insta...

Page 5: ...ing the operator 5 Fitting the Control Head 6 Fitting the Manual Override Lever 7 Fitting the Control Box 7 8 Fitting the optional Automatic Lock 8 Supply outlet information 8 Accessory wiring 8 Built...

Page 6: ...pending on the door position A significant advantage of the ZAP drive system with its soft start and its fast obstruction sensing is that when an object obstructs the door s travel the cables will pro...

Page 7: ...e the other end to the torque arm fixing hole on the Control Head use the supplied spacer if the offset is not enough to clear the drum Pic 5 Pic 5 Align the Control Head driven pulley s keyway with t...

Page 8: ...ecure the lever using the M5 screws and flange nuts supplied Pic 9 Pic 9 Place the hook in the cable D shackle or a convenient link of the chain and ensure that the lever is slightly above horizontal...

Page 9: ...d Pic 15 Pic 15 SUPPLY OUTLET A 115V 60Hz grounding type outlet is required for the 8825 R4 this should be installed by a qualified electrician in accordance with the local electrical codes within 4 o...

Page 10: ...AFETY and Pic 19 Note The supplied photo eyes are not polarity sensitive and can be wired either way around Pic 19 When the photo eyes are properly aligned the red safety light on the Control Box circ...

Page 11: ...rd stage to end 4 Once the third stage of the calibration process is complete the door will be closed and the Operator Light will be lit with the beeper sounding once every 5 seconds to indicate entry...

Page 12: ...obstruction A calibration reset pages 9 10 is required for a new setting to take effect Release the PROGRAM button after the fourth beep to program the closing speed change point 14 beeps representing...

Page 13: ...ILLUMINATED button after the first beep for vacation mode The light goes out and the radios and external inputs are all ignored until the button has been pressed again to leave vacation mode Release t...

Page 14: ...omatically opens REASON REMEDY A The V belt tension is too loose and the belt is slipping over the motor pulley Increase the tension by releasing the Manual Override Lever and screwing the hook in a f...

Page 15: ...e ZAP Controller has not been calibrated to this door Refer to the calibration process on pages 9 and 10 C The obstruction tolerance may be too low Refer to the Installer Programming instructions on p...