6-5
IM 77C01H01-10EN
Functions and Usage of D Registers
6
6.4 D Register Map
D-Reg
No.
Ref No.
H No.
Register
Symbol
Register Name
Effective Range
Initial
Value
Back-
up
R/W
D0043
40043
002A
VT L
VT ratio (float, lower 2 bytes)
1 to 6000
1
○
* R/W
D0044
40044
002B
VT H
VT ratio (float, upper 2 bytes)
* R/W
D0045
40045
002C
CT L
CT ratio (float, lower 2 bytes)
0.05 to 32000
1.00
○
* R/W
D0046
40046
002D
CT H
CT ratio (float, upper 2 bytes)
* R/W
D0047
40047
002E
LOWCUT L
Integral low-cut power (float, lower 2 bytes)
0.05 to 20.00 [%]
0.05
○
* R/W
D0048
40048
002F
LOWCUT H
Integral low-cut power (float, upper 2 bytes)
* R/W
D0049
40049
0030
PULSE1
Pulse unit-1 of electric energy (uint16)
1 to 50,000 [x10Wh/pls]
(Note 1)
100
○
* R/W
D0050
40050
0031
–
Do not use.
–
–
–
–
D0051
40051
0032
–
Do not use.
–
–
–
–
D0052
40052
0033
PULSE1
WIDTH
ON pulse width-1 of electric energy (uint8)
1 to 127 [x10ms]
(Note 1)
5
○
* R/W
D0053
40053
0034
INTEG START
STOP
Start/stop of integration
0: Start, 1: Stop
0
○
* R/W
D0054
40054
0035
–
Do not use.
–
–
–
–
D0055
40055
0036
–
Do not use.
–
–
–
–
D0056
40056
0037
–
Do not use.
–
–
–
–
D0057
40057
0038
kWh SET L
Active energy - setpoint (uint32, lower 2 bytes)
0 to 99,999,999 [kWh]
0 to 99,999,999 [Wh]
(Note 2)
0
X
W
D0058
40058
0039
kWh SET H
Active energy - setpoint (uint32, upper 2 bytes)
W
D0059
40059
003A
RMT RST
Remote reset
If other than 1: Invalid
If 1: UPM100 is hard-reset
0
X
W
D0060
40060
003B
kWh RST
Active energy reset
If other than 1: Invalid
If 1: Active energy
(D0001, D0002) is reset
0
X
W
D0061
40061
003C
MAX RST
Maximum/minimum values reset
If other than 1: Invalid
If 1: Maximum/minimum
values (D0023 to D0040)
are reset
0
X
W
D0062
40062
003D
Wh START
Start of optional integration
If other than 1: Invalid
If 1: Optional integration
(D0003 to D0006) starts
0
X
W
D0063
40063
003E
Wh STOP
Stop of optional integration
If other than 1: Invalid
If 1: Optional integration
(D0003, D0004) stops
0
X
W
D0064
40064
003F
RWh
Regenerative energy reset
If other than 1: Invalid
If 1: Regenerative energy
(D0067, D0068) is reset
0
–
W
D0065
40065
0040
–
Do not use.
–
–
–
–
D0066
40066
0041
–
Do not use.
–
–
–
–
D0067
40067
0042
RKWH L
Regenerative energy (uint32, lower 2 bytes)
0 to 99,999,999 [kWh]
0 to 99,999,999 [Wh]
(Note 2)
0
○
R
D0068
40068
0043
RKWH H
Regenerative energy (uint32, upper 2 bytes)
0
○
R
D0069
40069
0044
RWH SET L
Regenerative energy - setpoint (uint32, lower 2 bytes)
0
–
W
D0070
40070
0045
RWH SET H
Regenerative energy - setpoint (uint32, upper 2 bytes)
0
–
W
D0071
40071
0046
RWH STS
Regenerative energy writing status
If other than 1: Invalid
If 1: The values of D0069
and D0070 are written as
the integrated value
0
–
W
D0072
40072
0047
SET STS
Setup change status
If other than 1: Invalid
If 1: Initialization is
performed to validate setup
changes (D0043 to D0049,
D0052, D0085, D0087, and
D0088 are validated)
0
X
W
D0073
40073
0048
kWh STS
Active energy writing status
If other than 1: Invalid
If 1: The values of D0057
and D0058 are written as
the integrated value
0
X
W
Note 1: The UPM100-xx2xx and UPM100-xx3xx allow this register to be read and written.
Note 2: For the UPM100-xxxx0 to -xxxx3, the unit is [kWh].