8-22
IM 704420-01E
: D C O u t : J U D G e : R E S u l t ?
: D C O u t : J U D G e : R E S u l t ?
: D C O u t : J U D G e : R E S u l t ?
: D C O u t : J U D G e : R E S u l t ?
: D C O u t : J U D G e : R E S u l t ?
Function
Queries the determination result.
Syntax
:DCOut:JUDGe:RESult?
Example
:DCOUT:JUDGE:RESULT?
→
GO
Description This command can be used only when the DC
output mode is set to “
JUDGe
.”
• If the result is GO, “
GO
” is returned.
• If the result is NOGO, “
NOGO
” is returned.
• If the result is NOJUDGE, “
NOJUD
” is returned.
• If the PLL is turned ON, determination cannot
be performed until the clock signal is
regenerated from the data signal. If the clock
signal cannot be regenerated, “
NOJUD
” is
returned.
: D C O u t : M O D E
: D C O u t : M O D E
: D C O u t : M O D E
: D C O u t : M O D E
: D C O u t : M O D E
Function
Sets the DC output mode or queries the current
setting.
Syntax
:DCOut:MODE {JITTer|JUDGe}
:DCOut:MODE?
Example
:DCOUT:MODE JITTER
:DCOUT:MODE?
→
:DCOUT:MODE JITTER
: D I S P l a y ?
: D I S P l a y ?
: D I S P l a y ?
: D I S P l a y ?
: D I S P l a y ?
Function
Queries all settings related to the display.
Syntax
:DISPlay?
Example
:DISPLAY?
→
:DISPLAY:SCALE R10;
STATISTIC 1;UNIT NS
: D I S P l a y : M E A S u r e
: D I S P l a y : M E A S u r e
: D I S P l a y : M E A S u r e
: D I S P l a y : M E A S u r e
: D I S P l a y : M E A S u r e
Function
Sets the measured value to displayed or queries
the current setting.
Syntax
:DISPlay:MEASure {JITTer|SDEViation|
AVERage}
:DISPlay:MEASure?
Example
:DISPLAY:MEASURE JITTER
:DISPLAY:MEASURE
→
:DISPLAY MEASURE JITTER
: D I S P l a y : S C A L e
: D I S P l a y : S C A L e
: D I S P l a y : S C A L e
: D I S P l a y : S C A L e
: D I S P l a y : S C A L e
Function
Sets the scale of the analog meter or queries
the current setting.
Syntax
:DISPlay:SCALe {R10|R20}
:DISPlay:SCALE?
Example
:DISPLAY:SCALE R10
:DISPLAY:SCALE?
→
:DISPLAY:SCALE R10
8.7.5 DISPlay Group
The commands in this group deal with the display.
:DISPlay
:
SCALe
<Space>
R10
R20
?
STATistic
<Space>
OFF
ON
<NRf>
?
MEASure
<Space>
JITTer
SDEViation
AVERage
?
?
;
8.7 Commands
: D I S P l a y : S T A T i s t i c
: D I S P l a y : S T A T i s t i c
: D I S P l a y : S T A T i s t i c
: D I S P l a y : S T A T i s t i c
: D I S P l a y : S T A T i s t i c
Function
Turns ON/OFF the numeric display or queries
the current setting.
Syntax
:DISPlay:STATistic {Boolean}
:DISPlay:STATistic?
Example
:DISPLAY:STATISTIC ON
:DISPLAY:STATISTIC?
→
:DISPLAY:STATISTIC 1