10.8 General Specifications
Item
Specification
Standard operating conditions
Ambient temperature
23
±
5
°
C
Ambient humidity
50
±
10% RH
Error in supply voltage and
Within 1% of rating
frequency
Warm-up time
Approx. 30 minutes.
Storage conditions
Temperature
–20
°
C to 60
°
C
Humidity
20% to 80% RH (no condensation)
Operating conditions
Temperature
5
°
C to 40
°
C
Humidity
20% to 80%RH (no condensation)
Rated supply voltage
100 V to 240 VAC
Permitted supply voltage range 90 V to 264 VAC
Rated supply voltage frequency 50/60 Hz
Permitted supply voltage
48 Hz to 63 Hz
frequency range
Maximum power consumption
100 VA
Insulation resistance
10 M
Ω
or more (500 VDC)
(between power supply and case)
Withstanding voltage
1500 VAC at 50/60 Hz for one minute
(between power supply and case)
Signal ground
The ground of all input and output connectors are connected to the case ground. In addition,
all input terminals are protected using a diode.
Dimensions
Approx. 213(W)
×
132(H)
×
350 (D) mm excluding projections.
Weight
Approx. 5 kg (main unit only)
Cooling method
Forced air cooling
Installation position
Horizontal (stacking prohibited)
Battery backup
Setup information is backed up with the internal lithium battery
Key lock
Able to set key lock.
Standard Accessories
Power cord
1 piece
Rubber feet
1 set (2 pieces)
User’s manual
1 piece (this manual)
Safety standard
Complying standard
EN61010-1
Overvoltage Category (Installation Category)II
*1
Pollution degree 2
*2
Emission
Complying standard
EN55011-Group 1 Class A
This is Class A product(for industrial environment). In a domestic
environment this product may cause radio interference in which case
the user may be required to take adequate measures.
EN61000-3-2
Harmonics current
EN61000-3-3
Flicker and voltage fluctuations
Immunity
Complying standard
EN61326
Industrial locations
•
Cabels condition
The applied BNC cable, GP-IB cable and EXT I/O cable must be
shorter than 3 meters.
*1 Overvoltage Categories define transient overvoltage levels, including impulse withstand voltage levels.
Overvoltage Category I:
Applies to equipment supplied with electricity from a circuit containing an overvoltage control
device.
Overvoltage Category II: Applies to equipment supplied with electricity from fixed installations like a distribution board.
*2 Pollution Degree:
Applies to the degree of adhesion of a solid, liquid, or gas which deteriorates withstand voltage or
surface resistivity,
Pollution Degree 1:
Applies to closed atmospheres (with no, or only dry, non-conductive pollution).
Pollution Degree 2:
Applies to normal indoor atmospheres (with only non-conductive pollution).