6
-18
Acceleration and Deceleration Characteristics
This section explains the acceleration and deceleration characteristics of the Inverter.
Setting Acceleration and Deceleration Times
Acceleration time indicates the time taken for the output frequency to climb from 0% to 100%. Deceleration
time indicates the time taken for the output frequency to reduce to 0%. The factory setting of the acceleration
time is C1-01, and the factory setting of the deceleration time is C1-02.
Related Parameters
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
C1-01
Acceleration
time 1
Sets the acceleration time to accel-
erate from 0 to the maximum output
frequency, in 1-second units.
0.0 to
6000.0
*
10.0 s
Yes
Q
Q
Q
Q
Q
200H
Accel Time 1
C1-02
Deceleration
time 1
Sets the deceleration time to decel-
erate from the maximum output fre-
quency to 0, in 1-second units.
Yes
Q
Q
Q
Q
Q
201H
Decel Time 1
C1-03
Acceleration
time 2
The acceleration time when the
multi-function input “accel/decel
time 1” is set to ON.
Yes
A
A
A
A
A
202H
Accel Time 2
C1-04
Deceleration
time 2
The deceleration time when the
multi-function input “accel/decel
time 1” is set to ON.
Yes
A
A
A
A
A
203H
Decel Time 2
C1-05
Acceleration
time 3
The acceleration time when the
multi-function input “accel/decel
time 2” is set to ON.
No
A
A
A
A
A
204H
Accel Time 3
C1-06
Deceleration
time 3
The deceleration time when the
multi-function input “accel/decel
time 2” is set to ON.
No
A
A
A
A
A
205H
Decel Time 3
C1-07
Acceleration
time 4
The acceleration time when the
multi-function input “accel/decel
time 1” and “accel/decel time 2” are
set to ON.
No
A
A
A
A
A
206H
Accel Time 4
C1-08
Deceleration
time 4
The deceleration time when the
multi-function input “accel/decel
time 1” and “accel/decel time 2” are
set to ON.
No
A
A
A
A
A
207H
Decel Time 4
C1-10
Accel/decel
time setting
unit
0: 0.01-second units
1: 0.1-second units
0 or 1
1
No
A
A
A
A
A
209H
Acc/Dec
Units