Trial Operation Procedures
4-
11
Set the autotuning type.
Step
Digital Operator Display
1
Turn ON the power supply.
2
Press the MENU Key several times to access the autotuning display.
The autotuning display will not appear during operation or when a fault
has occurred.
3
Press the DATA/ENTER Key to display the T1-01 (Autotuning Mode
Selection) user constant setting.
4
Press the DATA/ENTER Key to display the current set value of T1-01.
5
Press the Increment Key and set the value to 0 (rotational autotuning).
6
Press the DATA/ENTER Key to confirm the value.