Parameter
Function
Default
Value
Required
value
Cat.
When
ena-
bled
No.
Dig
.
3
External Encoder Usage
0
0
M
After
restart
0
Do not use an external
encoder.
1
The external encoder
moves in the forward
direction for CCW motor
rotation.
2
Reserved setting (Do not
use.)
3
The external encoder
moves in the reverse
direction for CCW motor
rotation.
4
Reserved setting (Do not
use.)
Pn00B
Application Function Selections B -
-
-
-
3
Feedback Option Module Usage
0
1
M
After
restart
0
Used for external
encoder feedback
1
Used for motor encoder
feedback
Pn080
Application Function Selections
80
-
-
-
-
0
Polarity Sensor Selection
0
*1
O
After
restart
0
Use polarity sensor.
1
Do not use polarity
sensor.
1
Motor Phase Sequence Selection 0
*1
O
After
restart
0
Set a phase-A lead as a
phase sequence of U, V,
and W.
1
Set a phase-B lead as a
phase sequence of U, V,
and W.
Pn081
Application Function Selections
81
-
-
-
-
1
Encoder Pulse Output Usage
0
*1
O
After
restart
0
Enables the pulse output
function (Pn212)
1
Disables the pulse
output function
2
Coordination Setting between
Origin and U-phase position
0
*2
O
After
restart
Sigma-5 and Sigma-7 Series SERVOPACKs
SERVOPACK Set-up
SERVOPACK for Semi-closed Loop Control with Rotary Motor
| | Feedback Option Module Type 3 - Manual version C - Revision 0 | en |
77