6.2 Drive Alarms, Faults, and Errors
YASKAWA EUROPE SIEP
YASKAWA AC Drive L1000V Technical Manual
167
Tr
ouble
s
ho
ot
in
g
6
u
Alarm and Error Displays
n
Faults
gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is
important to distinguish between faults and alarms to determine the proper corrective actions.
When the drive detects a fault, the ALM indicator LED lights, the fault code appears on the digital operator, and the fault
contact MA-MB-MC changes state. An alarm is present if the ALM LED blinks and the fault code on the digital operator
flashes. Refer to
Minor Faults and Alarms on page 168
for a list of alarm codes.
Table 6.2 Fault Displays (1)
Digital Operator Display
Name
Page
Digital Operator Display
Name
Page
LED Operator
LCD Operator
LED Operator
LCD Operator
CF
Control Fault
GF
Ground Fault
CoF
Current Offset Fault
LF
Output Phase Loss
,
CPF00,
CPF01
Control Circuit Error
LF2
Output Current Imbalance
oC
Overcurrent
CPF02
A/D Conversion Error
oH
Heatsink Overheat
CPF03
Control Board Connection Error
oH1
Heatsink Overheat
CPF06
EEPROM Data Error
oL1
Motor Overload
,
CPF07,
CPF08
Terminal Board Connection Error
oL2
Drive Overload
oL3
Overtorque Detection 1
CPF11
RAM Fault
oL4
Overtorque Detection 2
CPF12
FLASH Memory Fault
oPr
Operator Connection Fault
CPF13
Watchdog Circuit Exception
oS
Overspeed (simple PG feedback control
modes)
CPF14
Control Circuit Fault
ov
DC Bus Overvoltage
CPF16
Clock Fault
PF
Input Phase Loss
CPF17
Timing Fault
PGo
Encoder Disconnected (simple PG
feedback control modes)
CPF18
Control Circuit Error
rr
Dynamic Braking Transistor Fault
CPF19
Control Circuit Error
SE1
Motor Contactor Response Error
,
CPF20,
CPF21
Control Circuit Error
SE2
Starting Current Error
SE3
Output Current Error
CPF22
A/D Conversion Error
SE4
Brake Response Error
CPF23
Control Board Connection Error
UL3
Undertorque Detection 1
CPF24
Drive Unit Signal Fault
UL4
Undertorque Detection 2
dEv
Excessive Speed Deviation (simple PG
feedback control modes)
Uv1
DC Bus Undervoltage
to
EF3 to
EF7
External Fault (input terminal S3 to S7)
Uv2
Control Power Supply Voltage Fault
Uv3
Soft Charge Circuit Fault
Err
EEPROM Write Error
voF
Output Voltage Detection Error
Summary of Contents for Lift Inverter L1000V
Page 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...