Drive Replacement
u
Serviceable Parts
The drive contains few serviceable parts. The following parts can be replaced over the life span of the drive:
• Main Control board and I/O Terminal board PCBs
• Cooling fan(s)
• Front cover
u
Terminal Board
CAUTION! Crush Hazard. Carrying the drive by the front cover may cause the main body of the drive to fall, resulting in minor or
moderate injury. Always hold the case when carrying the drive.
The drive has a modular I/O terminal block that facilitates quick drive replacement. The terminal board contains on-
board memory that stores all drive parameter settings and allows the parameters to be saved and transferred to the
replacement drive. To transfer the terminal board, disconnect the terminal board from the damaged drive then reconnect
it to the replacement drive. Once transferred, there is no need to manually reprogram the replacement drive.
Note:
If the damaged drive and the new replacement drive are have different capacities, the data stored in the terminal board cannot be
transferred to the new drive and an oPE01 error will appear on the display. The control terminal board can still be used, but
parameter setting from the old drive cannot be transferred. The replacement drive must be initialized and manually programmed.
Figure 7.6
Figure 7.6 Terminal Board Location
A – Charge LED
C – Terminal Board Locking Pin
B – Removable Terminal Board
D – Ground Cable Pin
A
B
C
D
MD
AM AC RP AC
S7 HC SC H1 PC P1
ME
MF
MA
MB
MC
CN1
S2 S3 S4 S5 S6
S1
Summary of Contents for Lift Inverter L1000V
Page 4: ...4 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 28: ...1 4 Component Names 28 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 62: ...3 10 Wiring Checklist 62 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 162: ...5 12 U Monitor Parameters 162 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 279: ...8 YASKAWA EUROPE SIEP YASKAWA AC Drive L1000V Technical Manual...
Page 281: ...10 YASKAWA ELECTRIC SIEP C710616 33C YASKAWA AC Drive L1000A Technical Manual...