5.3 C: Tuning
116
YASKAWA EUROPE SIEP
YASKAWA AC Drive L1000V Technical Manual
Figure 5.9
Figure 5.9 Settings at Low and High Speed during Deceleration (Leveling Speed is Selected)
n
C5-40: ASR Start Speed
Sets the speed level from which the ASR Slip Compensation starts to operate while the Standard Slip Compensation
(C3-
) is shut down. This function is only activated when in simple closed loop control (H6-01=3)
u
C6: Carrier Frequency
n
C6-02: Carrier Frequency Selection
Sets the carrier frequency for the PWM output.
1: 2.0 kHz
2: 5.0 kHz
3: 8.0 kHz
4: 10.0 kHz
5: 12.5 kHz
6: 15.0 kHz
Note:
Refer to Carrier Frequency Derating on page 220
when using a carrier frequency setting above 8.0 kHz.
No.
Parameter Name
Setting Range
Default
C5-40
ASR Start Speed
0.0 to 100.00 %
2.50 %
No.
Parameter Name
Setting Range
Default
C6-02
Carrier Frequency Selection
1 to 6
3