3.5 Protective Covers
YASKAWA EUROPE
SIEP
YASKAWA AC Drive L1000V Technical Manual
49
3
3.
To remove the conduit bracket loosen the two screws that attach it to the drive enclosure.
Figure 3.9
Figure 3.8 Removing the Conduit Bracket
n
Reattaching the Protective Covers
Pass power wiring and control signal wiring through the exit holes in the bottom of the conduit bracket of the drive. Place
power wiring and control signal wiring in separate conduits. Properly connect all wiring after installing the drive and
connecting other devices. Reattach all protective covers when wiring is complete.
Figure 3.10
Figure 3.9 Reattaching the Protective Covers