Higher Speed Priority is Selected and the Leveling Speed Input is Not Assigned (d1-18 = 1 and H1-
≠
53)
The drive decelerates to the leveling speed (d1-26) when the selected speed reference signal is removed.
If no speed reference is selected at start, the drive will trigger an “FrL” fault. Set parameter S6-15 to 0 to disable Speed
Reference Missing (FrL) detection. With this setting the drive starts using leveling speed if no other speed reference is
selected.
Leveling Speed has Priority and the Leveling Speed Input is Assigned (d1-18 = 2, H1-
= 53)
The leveling signal has priority over other speed references. The drive decelerates to the leveling speed (d1-26) when the
leveling speed selection input is activated. The drive stops when either the leveling input or the Up/Down command is
released.
Leveling Speed Priority is Selected and the Nominal Speed Input is Not Assigned (d1-18 = 2, H1-
≠
50)
The drive runs at nominal speed (d1-19) when no speed selection input is set. When the leveling speed signal is set, the
drive decelerates to the leveling speed. The leveling speed signal has priority over all other speed signals.
NOTICE:
Equipment Hazard. This function may not work properly if a broken wire connection to the drive I/O causes improper elevator
speed selection. Properly tighten wire connections at the drive terminals before enabling this function.
■
Multi-Function Terminal Setup
Multi-Function Digital Input (Terminals S3 to S8)
The H1 parameters assign functions to digital input terminals S3 to S8 digital input terminal functions, refer to
Multi-Function Digital Inputs on page 183
.
Multi-Function Digital Outputs
The H2 parameters assign functions to digital output terminals M1-M2, M3-M4, M5-M6, P1-C1, and P2-PC digital input
terminal functions, refer to
H2: Multi-Function Digital Outputs on page 185
Multi-Function Analog Inputs
The H3 parameters assign functions to analog input terminals A1 and A2 analog input functions, refer to
Multi-Function Analog Inputs on page 187
.
DC Injection/
Position lock
DC Injection/
Position lock
Up/Down Command
Selected speed (other than leveling)
Speed
Safe disable (terminals H1/H2 on)
and Baseblock off (H1-
= 8/9)
Input is set
DC Injection/
Position lock
DC Injection/
Position lock
Leveling speed has priority
Up/Down Command
Leveling speed
Selected speed (other than leveling)
Speed
Safe disable (terminals H1/H2 on)
and Baseblock off (H1-
= 8/9)
Input is set
No effect
DC Injection/
position lock
DC Injection/
position lock
Up/Down Command
Leveling speed
Speed
Safe disable (terminals H1/H2 on)
and Baseblock off (H1-
= 8/9)
Input is set
TOEP_C710616_38H_7_0.book 85 ページ 2015年11月11日 水曜日 午後7時40分