B Parameter Table
YASKAWA ELECTRIC
TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
173
Par
ame
te
r Ta
ble
B
◆
d: Speed References
Speed Reference parameters are used to set the various speed reference values during operation.
■
d1: Speed Reference
No.
Name
Description
Setting
d1-01
Speed Reference 1
Sets the Speed reference for the drive when d1-18 is set to 0 or 3. Setting units are
determined by parameter o1-03.
Min: 0.00%
Max: 100.00%
d1-02
Speed Reference 2
d1-03
Speed Reference 3
d1-04
Speed Reference 4
d1-05
Speed Reference 5
d1-06
Speed Reference 6
d1-07
Speed Reference 7
d1-08
Speed Reference 8
d1-18
Speed Reference Selection
Mode
Sets the mode of speed reference selection by digital inputs.
0: Use multi-speed references (d1-01 to d1-08)
1: High speed reference has priority (d1-19 to d1-23, d1-26)
2: Leveling speed reference has priority (d1-19 to d1-23, d1-26)
3: Use multi-speed references d1-02 to d1-08, no speed selection stops the drive.
Drive will stop when all input terminals programmed for speed references (H1-
=
3, 4, 5) are open.
Default: 0
Min: 0
Max: 3
d1-19
Nominal Speed
Sets the nominal speed reference when d1-18 = 1 or 2.
Default:
100.00%
Min: 0.00%
Max: 100.00%
d1-20
Intermediate Speed 1
Sets intermediate speed reference 1 when d1-18 = 1 or 2.
Min: 0.00%
Max: 100.00%
d1-21
Intermediate Speed 2
Sets intermediate speed reference 2 when d1-18 = 1 or 2.
Min: 0.00%
Max: 100.00%
d1-22
Intermediate Speed 3
Sets intermediate speed reference 3 when d1-18 = 1 or 3.
Min: 0.00%
Max: 100.00%
d1-23
Releveling Speed
Sets speed reference for releveling when d1-18 = 1 or 2.
Min: 0.00%
Max: 100.00%
d1-24
Inspection Operation
Speed
Sets speed reference when inspection operation is enabled.
Default:
50.00%
Min: 0.00%
Max: 100.00%