L1-03 Motor Overload Alarm Operation Selection
L1-04 Motor Overload Fault Operation Selection
◆
Safe Disable Input Function
This section explains the Safe Disable function and how to use it in an elevator installation. Contact Yaskawa if more
information is required.
■
Safety Standards
The TUV mark indicates compliance with safety standards.
Figure 100
Figure 109 TUV mark
Standard Models (CIMR-L
A
)
Table 69 Safety Standards and Applicable Harmonized Standards for CIMR-L
A
Models in Compliance with IEC/EN 61508 SIL3 (CIMR-L
F
)
Table 70 Safety Standards and Applicable Harmonized Standards for CIMR-L
F
The Safe Disable function is in compliance with these standards.
Setting
Description
0
Ramp to Stop
1
Coast to Stop
2
Fast-Stop
3
Alarm Only (default setting)
Setting
Description
0
Ramp to Stop
1
Coast to Stop (default setting)
2
Fast-Stop
Safety Standards
Applicable Harmonized Standards
Functional Safety
IEC/EN 61508 series (SIL2)
IEC/EN 61800-5-2 (SIL2)
Safety of Machinery
ISO/EN ISO 13849-1/AC: 2009 (PL d (Cat.3))
EMC
EN 61800-3: 2004/A1: 2012
IEC 61800-3: 2004/A1: 2011
Safety Standards
Applicable Harmonized Standards
Functional Safety
IEC/EN 61508 series: 2010 (SIL3)
IEC/EN 62061: 2005 (SILCL3)
IEC/EN 61800-5-2: 2007 (SIL3)
Safety of Machinery
ISO/EN ISO 13849-1/AC: 2009 (PL e (Cat.3))
EMC
IEC/EN 61326-3-1: 2008 (EMC-related)