6.6 Replacing Power Cells
YASKAWA ELECTRIC
TOEP C710687 02B FSDrive-MV1000 Instructions
205
Pe
ri
od
ic
In
spe
ct
io
n
&
Main
tenan
ce
6
Figure 6.5
Figure 6.6
Figure 6.5 Drawing Out a Power Cell
7.
Secure the Power Cell on the platform with a belt or other means to prevent falling and move the Power Cell to a
stable position.
Figure 6.7
Figure 6.8
Figure 6.6 Moving A Power Cell
Figure 6.9
Figure 6.10
Figure 6.7 Safety Rails to Prevent the Power Cell from Falling
Note:
Safety rails to prevent the Power Cell from falling are removable. Insert the rails according to the position of the Power Cell.
A – Drive
D – Fix the lifter at the appropriate height for
the Power Cell.
B – Power Cells
E – Pull the Power Cell out about 100 mm
toward front.
C – Lifter
F – Safety rail to prevent the Power Cell
from falling (provided with lifter)
A – Drive
C – Belt to prevent the Power Cell
from falling
B – Lifter
A – Lifter (bucket)
C – Position to insert safety
rails
B – Two safety rails to prevent
the Power Cell from falling
(provided with lifter)
C
C
D
D
A
A
E
E
F
B
B
<
Power Cell Placed Horizontally
>
<
Power Cell Placed Vertically
>
Asia
B
B
C
C
A
A
<
Power Cell Placed Horizontally
>
<
Power Cell Placed Vertically
>
Asia
A
B
C
C
Asia
Summary of Contents for FSDrive-MV1000 Series
Page 8: ...8 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 106: ...3 9 Wiring Check 106 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 210: ...6 7 Spare Parts 210 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 222: ...B 1 European Standards 222 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...