5.2 Motor Performance Fine-Tuning
YASKAWA ELECTRIC
TOEP C710687 02B FSDrive-MV1000 Instructions
141
T
ro
ubles
hoo
ting
5
When using Open Loop Vector Control, leave the torque compensation gain (C4-01) at its default setting of 1.00.
In the Open Loop Vector Control, when the speed precision is not improved for regenerative operation, enable slip
compensation during regeneration by setting parameter C3-04 to 1.
• Overvoltage trips when
accelerating, decelerating,
or during sudden speed or
load changes.
Speed Feedback
Detection Control
(AFR) Time Constant
2
(n2-03)
• Gradually increase the setting in 50 ms increments if
overvoltage trips occur.
• Gradually reduce the setting in 10 ms increments if response
is slow.
Note:
Ensure that n2-02
≤
n2-03.When changing
n2-03, increase the value of
C4-06, Torque Compensation Primary Delay
Time 2, proportionally.
750 ms
750 to
2000 ms
Torque Compensation
Primary Delay Time 2
(C4-06)
• Gradually increase the setting in 10 ms increments and check
the performance if overvoltage trips occur.
• Gradually reduce the setting in 2 ms increments and check
the performance if response is slow.
Note:
Ensure that C4-02
≤
C4-06. When changing
C4-06, increase the value of
n2-03 proportionally.
150 ms
150 to
750 ms
• Poor motor torque and
speed response
• Motor hunting and
oscillation
Torque Compensation
Primary Delay Time
(C4-02)
• Gradually reduce the setting by 2 ms if motor torque and
speed response are too slow.
• Gradually increase the setting by 10 ms if motor hunting and
oscillation occur.
Note:
Ensure that C4-02
≤
C4-06. When changing
C4-02, increase the value of
n2-02, AFR Time Constant 1,
proportionally.
50 ms
20 to
Poor speed response and
stability
Slip Compensation
Primary Delay Time
(C3-02)
• Gradually reduce the setting in 10 ms increments if response
is slow.
• Gradually increase the setting in 10 ms increments if speed is
unstable.
200 ms
100 to
500 ms
Poor speed precision
Slip Compensation
Gain
(C3-01)
• Gradually increase the setting in 0.1 ms increments if speed
is too slow.
• Gradually reduce the setting in 0.1 ms increments if speed is
too fast.
1.0
0.5 to 1.5
• Poor motor torque at low
speeds
• Poor speed response
• Motor instability at start
Mid Output
Frequency Voltage
(E1-08)
Minimum Output
Frequency Voltage
(E1-10)
• Increase the setting if motor torque and speed response are
too slow.
• Reduce the setting if the motor exhibits excessive instability
at motor start.
Note:
When working with a relatively light load,
increasing this value too much can cause
overtorque.
E1-08:
E1-10:
±1% of the
motor rated
voltage
<1> Determined by o2-04 (Drive Model Selection)
Problem
Parameter No.
Corrective Action
Default
Suggested
Setting
Summary of Contents for FSDrive-MV1000 Series
Page 8: ...8 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 106: ...3 9 Wiring Check 106 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 210: ...6 7 Spare Parts 210 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...
Page 222: ...B 1 European Standards 222 YASKAWA ELECTRIC TOEP C710687 02B FSDrive MV1000 Instructions...