11.1 List of Parameters
11.1.2 List of Parameters
11-7
11
Parameter List
Pn40D
2
Second Stage
Notch Filter Q
Value
50 to 1,000
0.01
70
Immedi-
ately
Tuning
Pn40E
2
Second Stage
Notch Filter Depth
0 to 1,000
0.001
0
Immedi-
ately
Tuning
Pn460
2
Notch Filter
Adjustment
Selections
0000h to
0101h
−
0101h
Immedi-
ately
Tuning
Pn502
2
Rotation
Detection Level
1 to 10,000
1 min
-1
30
Immedi-
ately
Setup
Pn503
2
Speed
Coincidence
Detection Signal
Output Width
0 to 100
1 min
-1
30
Immedi-
ately
Setup
−
Pn506
2
Brake
Reference-SERVO
OFF Delay Time
0 to 50
10 ms
0
Immedi-
ately
Setup
−
Pn507
2
Brake Reference
Output Speed
Level
0 to 10,000
1 min
-1
100
Immedi-
ately
Setup
−
Pn508
2
SERVO OFF-
Brake Reference
Waiting Time
10 to 100
10 ms
50
Immedi-
ately
Setup
−
Pn51E
2
Position Deviation
Overflow Warning
Level
10 to 100
1%
100
Immedi-
ately
Setup
Pn520
4
Position Deviation
Overflow Alarm
Level
1 to
1,073,741,823
1 refer-
ence unit
25600
Immedi-
ately
Setup
Pn526
4
Position Deviation
Overflow Alarm
Level at SERVO
ON
1 to
1,073,741,823
1 refer-
ence unit
25600
Immedi-
ately
Setup
Pn528
2
Position Deviation
Overflow Warning
Level at SERVO
ON
10 to 100
1%
100
Immedi-
ately
Setup
Pn529
2
Speed Limit Level
at SERVO ON
0 to 10,000
1 min
-1
10000
Immedi-
ately
Setup
Pn52B
2
Overload Warning
Level
1 to 100
1%
20
Immedi-
ately
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
When
Enabled
Classi-
fication
Reference
n.
X
Notch Filter Adjustment Selection 1
0
Do not adjust the first stage notch filter automatically during execution of custom
tuning.
1
Adjust the first stage notch filter automatically during execution of custom tuning.
n.
X
Reserved parameter (Do not change.)
n.
X
Notch Filter Adjustment Selection 2
0
Do not adjust the second stage notch filter automatically during execution of cus-
tom tuning.
1
Adjust the second stage notch filter automatically during execution of custom tun-
ing.
n.X
Reserved parameter (Do not change.)