5.5 Settings for References
5.5.1 Smoothing
5-33
5
Setup
5.5
Settings for References
5.5.1
Smoothing
Smoothing allows you to apply a filter to the position reference to produce smoother Servomo-
tor operation.
Note: Smoothing does not affect the travel distance.
The following parameters are related to smoothing.
*
The filter is disabled if you set the parameter to 0.
Note: Change the setting only when the motor is stopped.
Pn217
Average Position Reference Movement Time
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 10,000
0.1 ms
0
*
Immediately after
the motor stops
Setup
Pn217
Before filter
After filter
Pn217
Time
Speed
Target speed