11.1 List of Parameters
11.1.2 List of Parameters
11-12
PnBA2
2
/STOP
(Program Table
Operation Stop
Input)
Signal Allocation
0000h to
00C3h
−
0020h
After
restart
Setup
PnBA3
2
/JOGP
(Forward Jog
Input)
Signal Allocation
0000h to
00C3h
−
0050h
After
restart
Setup
PnBA4
2
/JOGN
(Reverse Jog
Input)
Signal Allocation
0000h to
00C3h
−
0060h
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
When
Enabled
Classi-
fication
Reference
n.
X
Signal Usage Method
0
Stop program table operation when the /STOP signal turns ON (closes).
1
Stop program table operation when the /STOP signal turns OFF (opens).
2, 3
Program table operation is not stopped.
n.
X
Signal Terminal Number
Same as PnBA0 = n.
X
.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Signal Usage Method
0
Jog forward while the input signal is ON (closed).
1
Jog forward while the input signal is OFF (open).
2, 3
Forward jog operation is not performed.
n.
X
Signal Terminal Number
Same as PnBA0 = n.
X
.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Signal Usage Method
0
Jog in reverse while the input signal is ON (closed).
1
Jog in reverse while the input signal is OFF (open).
2, 3
Reverse jog operation is not performed.
n.
X
Signal Terminal Number
Same as PnBA0 = n.
X
.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)