C.9 MEMOBUS/Modbus Data Table
182
YASKAWA ELECTRIC
TOEP C710656 10B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
00DBH
oFA3
Contents (CN5-A)
bit 0
Communication ID Error (oFA30)
bit 1
Model Code Error (oFA31)
bit 2
Sumcheck Error (oFA32)
bit 3
Communication option timeout waiting for response (oFA33)
bit 4
MEMOBUS/Modbus Timeout (oFA34)
bit 5
Unit timeout waiting for response (oFA35)
bit 6
CI Check Error (oFA36)
bit 7
Unit timeout waiting for response (oFA37)
bit 8
Control Command Selection Error (oFA38)
bit 9
Unit timeout waiting for response (oFA39)
bit A
Control Response Selection 1 Error (oFA40)
bit B
Unit timeout waiting for response (oFA41)
bit C
Control Response Selection 2 Error (oFA42)
bit D
Control Response Selection Error (oFA43)
bit E, F
Reserved
00DCH - 00FBH
Reserved
<1> Communication error contents are saved until the fault is reset.