6.4 Cooling Fans
114
YASKAWA ELECTRIC
TOEP C710656 10B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
◆
Cooling Fan Replacement
WARNING!
Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious
personal injury. Before servicing the regenerative unit, disconnect all power to the equipment. The internal capacitor remains charged
even after the power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the regenerative
unit before touching any components.
CAUTION!
Burn Hazard. Do not touch a hot regenerative unit heatsink. Failure to comply could result in minor or moderate injury. Shut
off the power to the regenerative unit when replacing the cooling fan. To prevent burns, wait at least 15 minutes and ensure the
heatsink has cooled down.
NOTICE:
Follow cooling fan replacement instructions. Improper fan replacement could cause damage to equipment. Make sure the
fan is facing upwards when installing the replacement fan into the regenerative unit. Replace all fans when performing maintenance to
help ensure maximum useful product life.
■
2A03P5 to 2A0028, 4A03P5 to 4A0028
Removing the Cooling Fan Finger Guard and Cooling Fan
1.
Depress the right and left sides of the fan cover tabs and pull upward. Remove the fan cover from the top of the
regenerative unit. The following figure illustrates a regenerative unit with a single cooling fan.
Figure 6.2
Figure 6.2 Remove the Cooling Fan Finger Guard: 2A03P5 to 2A0028, 4A03P5 to 4A0028
2.
Remove the cooling fan cartridge. Disconnect the pluggable connector and remove the fan.
Figure 6.3
Figure 6.3 Remove the Cooling Fan: 2A03P5 to 2A0028, 4A03P5 to 4A0028
R1000
R1000
TOEP_C710656_10B_1_0.book 114 ページ 2015年1月8日 木曜日 午後8時55分