4.3 The Drive and Programming Modes
68
YASKAWA ELECTRIC
TOEP C710656 10B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
◆
Switching Between LOCAL and REMOTE
LOCAL mode is when the regenerative unit is set to accept the Run command from the digital operator RUN key.
REMOTE mode is when the regenerative unit is set to accept the Run command from an external device.
Switch the operation between LOCAL and REMOTE using the
key on the digital operator or via a digital input.
Note: 1.
After selecting LOCAL, the LO/RE light will remain lit.
2.
The regenerative unit will not allow the user to switch between LOCAL and REMOTE during run.
■
Using the LO/RE Key on the Digital Operator
■
Using Input Terminals S1 through S8 to Switch between LOCAL and REMOTE
It is possible to switch between LOCAL and REMOTE modes using one of the digital input terminals S1 through S8 (set
the corresponding parameter H1-
to “1”).
Setting H1-
to 1 disables the LO/RE key on the digital operator.
Step
Display/Result
1
Turn on the power to the regenerative unit. The initial display appears.
2
Press
. The LO/RE light will light up. The regenerative unit is now in LOCAL.
To set the regenerative unit for REMOTE operation, press the key again.
ALM
DIGITAL OPERATOR JVOP-182
REV
DRV
FOUT
DRV
YEC
OFF
Illuminated
LO
RE
ESC
RUN
STOP
ENTER
RESET
ALM
DIGITAL OPERATOR JVOP-182
REV
DRV
FOUT
DRV
YEC