6.4 Cooling Fans
116
YASKAWA ELECTRIC
TOEP C710656 10B YASKAWA Power Regenerative Unit - R1000 Instruction Manual
■
2A0035, 4A0035, 4A0043
Removing the Cooling Fan Finger Guard and Cooling Fan
1.
While pressing in on the hooks located on the left and right sides of the fan finger guard, free the fan finger guard
leading by lifting the back end first.
Figure 6.7
Figure 6.7 Remove the Cooling Fan Finger Guard: 2A0035, 4A0035, 4A0043
2.
Lift out the back end of the fan finger guard first. Unplug the replay connector and free the fan finger guard from
the regenerative unit.
Figure 6.8
Figure 6.8 Remove the Cooling Fan: 2A0035, 4A0035, 4A0043
Installing the Cooling Fan
Reverse the procedure described above to reinstall the cooling fan.
1.
Properly connect the fan power lines.
2.
Place the power supply connectors and cable back into the recess of the regenerative unit.
Figure 6.9
Figure 6.9 Cooling Fan Power Supply Connectors: 2A0035, 4A0035, 4A0043
A – Back
B – Front
Lift the fan finger
guard out of the
regenerative unit
leading with the
back end.
D1000
A
B
TOEP_C710656_10B_1_0.book 116 ページ 2015年1月8日 木曜日 午後8時55分