9 Input Assemblies (Drive Produces)
YASKAWA ELECTRIC
SIEP C730600 58A 1000-Series Option SI-EN3 Technical Manual
EN 33
Input Instance Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
166
0
Faulted
Alarm
Ready
Speed Agree
Fault Reset REV Running Zero Speed
Running
1
ZSV
–
Multi-
Function
Photo-
Coupler 2
Multi-
Function
Photo-
Coupler 1
Multi-
Function
Digital Output
LOCAL/
REMOTE
Uv
oPE
2
Motor Speed (Low Byte)
3
Motor Speed (High Byte)
4
Torque Actual (Low Byte)
5
Torque Actual (High Byte)
6
PG Count Value (Low Byte)
7
PG Count Value (High Byte)
8
Frequency Command (Low Byte)
9
Frequency Command (High Byte)
10
Output Frequency (Low Byte)
11
Output Frequency (High Byte)
12
Output Current (Low Byte)
13
Output Current (High Byte)
14
Terminal A1 Input (Low Byte)
15
Terminal A1 Input (High Byte)
16
Main Circuit DC Voltage (Low Byte)
17
Main Circuit DC Voltage (High Byte)
18
Error Code (Low Byte)
19
Error Code (High Byte)
20
Parameter F7-33
Default: Alarm Code (Low Byte)
21
Parameter F7-33
Default: Alarm Code (High Byte)
22
Parameter F7-34
Default: Output Power (Low Byte)
23
Parameter F7-34
Default: Output Power (High Byte)
24
Parameter F7-35
Default: Terminal A2 Input (Low Byte)
25
Parameter F7-35
Default: Terminal A2 Input (High Byte)
26
Parameter F7-36
Default: Terminal S1 to S8 Input (Low Byte)
27
Parameter F7-36
Default: Terminal S1 to S8 Input (High Byte)
28
Parameter F7-37
Default: Terminal A3 Input (Low Byte)
29
Parameter F7-37
Default: Terminal A3 Input (High Byte)
30
Parameter F7-38
Default: PG Counter (Ch2) (Low Byte)
31
Parameter F7-38
Default: PG Counter (CH2) (High Byte)