8 Output Assemblies (Drive Consumes)
YASKAWA ELECTRIC
SIEP C730600 58A 1000-Series Option SI-EN3 Technical Manual
EN 25
Output
Instance
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
116
0
Multi-
Function
Input 8
Multi-
Function
Input 7
Multi-
Function
Input 6
Multi-
Function
Input 5
Multi-
Function
Input 4
Multi-
Function
Input 3
Run
Rev
Run
Fwd
1
Multi-
Function
Photo
Coupler 2
Multi-
Function
Photo
Coupler 1
Multi-
Function
Digital
Output
–
–
–
Fault
Reset
External
Fault
2
Speed Reference (Low Byte)
3
Speed Reference (High Byte)
4
Torque Reference/Torque Limit (Low Byte)
5
Torque Reference/Torque Limit (High Byte)
6
Torque Compensation (Low Byte)
7
Torque Compensation (High Byte)
8
(Reserved)
9
–
–
–
–
Multi-
Function
Input 12
Multi-
Function
Input 11
Multi-
Function
Input 10
Multi-
Function
Input 9
10
–
–
–
–
–
–
NetCtrl
NetRef
11
–
–
–
–
–
–
–
–
12
Analog Output 1 (Low Byte)
13
Analog Output 1 (High Byte)
14
Analog Output 2 (Low Byte)
15
Analog Output 2 (High Byte)
16
Digital Outputs (Low Byte)
17
Digital Outputs (High Byte)
18
Reserved
19
Reserved
20 - 21
Programmable Bytes
Defined by F7-23
Default: Not Used
22 -23
Programmable Bytes
Defined by F7-24
Default: Not Used
24 - 25
Programmable Bytes
Defined by F7-25
Default: Not Used
26 - 27
Programmable Bytes
Defined by F7-26
Default: Not Used
28 - 29
Programmable Bytes
Defined by F7-27
Default: Not Used
30 - 31
Programmable Bytes
Defined by F7-28
Default: Not Used
32 - 33
Programmable Bytes
Defined by F7-29
Default: Not Used
116
34 - 35
Programmable Bytes
Defined by F7-30
Default: Not Used
36 - 37
Programmable Bytes
Defined by F7-31
Default: Not Used
38 - 39
Programmable Bytes
Defined by F7-32
Default: Not Used
40 - 43
Not Used