Check the Power Trim Pump
Fluid
NOTICE: ALWAYS check the oil level with
stern-drive in the full DOWN / TRIM-IN
position.
1. Place the stern-drive in full DOWN /
TRIM-IN position.
2. Observe the oil level in the reservoir.
The oil level should be maintained
within the MIN and MAX lines on the
reservoir (Figure 4, (2)).
0006012
(1)
(2)
Figure 4
1 – Reservoir
2 – MIN and MAX Lines
3. The oil level is low if it is below the MIN
line (Figure 4, (1)) on the reservoir. Fill
as necessary with the specified fluid.
See Fill the Power Trim Pump Fluid on
page 28.
0006013
(1)
Figure 5
1 – MIN Line
Fill the Power Trim Pump Fluid
Note: The power trim fluid does not require
changing unless it becomes contaminated
with water or debris. Contact your
authorized Yanmar Marine dealer or
distributor if the power trim fluid needs to be
changed.
1. Place the stern-drive in the full DOWN /
TRIM-IN position.
2. Unscrew and remove the fill cap
(Figure 6, (1)) assembly from the
reservoir (Figure 6, (3)) with specified
fluid.
Description
Where Used
Dextron 3 Automatic
Transmission Fluid
Power Trim Pump
STERN-DRIVE OPERATION
28
ZT350 Operation Manual
© 2008 Yanmar Marine International