Charging system
Control system
Item
Unit
Model
VX 700
Charge coil
Output peak voltage
at cranking (unloaded)
V
180
at cranking (loaded)
V
20
at 1500 r/min (loaded)
V
210
at 3500 r/min (loaded)
V
150
Resistance (*1)
at 20 °C (68 °F)
Ω
497.7–608.3
Lighting coil
Output peak voltage
at cranking (unloaded)
V
8.7
at 1500 r/min (unloaded)
V
25.6
at 3500 r/min (unloaded)
V
47.3
Resistance (*1)
at 20 °C (68 °F)
Ω
1.143–1.397
Minimum charging
current
A at r/min
14 at 6000
Rectifier regulator
Output peak voltage
at 3500 r/min (loaded)
V
13.0
(*1) The figures are for reference only.
Item
Unit
Model
VX 700
Ignition coil
Primary coil resistance
at 20 °C (68 °F)
Ω
0.078–0.106
Secondary coil resistance
at 20 °C (68 °F)
k
Ω
14.336–30.464
Thermoswitch (engine)
Input voltage (*1)
V
11.0–12.0
Continuity temperature
°C (°F)
77–83 (171–181)
No continuity temperature
°C (°F)
63–77 (145–171)
(*1) The figures are for reference only.